Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth
Joint Authors
Hernandez-Meza, Gabriela
Izzetoglu, Meltem
Osbakken, Mary
Izzetoglu, Kurtulus
Green, Michael S.
Source
Issue
Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-11, 11 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2015-10-01
Country of Publication
Egypt
No. of Pages
11
Main Subjects
Abstract EN
The standard-of-care guidelines published by the American Society of Anesthesiologists (ASA) recommend monitoring of pulse oximetry, blood pressure, heart rate, and end tidal CO2 during the use of anesthesia and sedation.
This information can help to identify adverse events that may occur during procedures.
However, these parameters are not specific to the effects of anesthetics or sedatives, and therefore they offer little, to no, real time information regarding the effects of those agents and do not give the clinician the lead-time necessary to prevent patient “awareness.” Since no “gold-standard” method is available to continuously, reliably, and effectively monitor the effects of sedatives and anesthetics, such a method is greatly needed.
Investigation of the use of functional near-infrared spectroscopy (fNIRS) as a method for anesthesia or sedation monitoring and for the assessment of the effects of various anesthetic drugs on cerebral oxygenation has started to be conducted.
The objective of this paper is to provide a thorough review of the currently available published scientific studies regarding the use of fNIRS in the fields of anesthesia and sedation monitoring, comment on their findings, and discuss the future work required for the translation of this technology to the clinical setting.
American Psychological Association (APA)
Hernandez-Meza, Gabriela& Izzetoglu, Meltem& Osbakken, Mary& Green, Michael S.& Izzetoglu, Kurtulus. 2015. Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth. BioMed Research International،Vol. 2015, no. 2015, pp.1-11.
https://search.emarefa.net/detail/BIM-1057313
Modern Language Association (MLA)
Hernandez-Meza, Gabriela…[et al.]. Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth. BioMed Research International No. 2015 (2015), pp.1-11.
https://search.emarefa.net/detail/BIM-1057313
American Medical Association (AMA)
Hernandez-Meza, Gabriela& Izzetoglu, Meltem& Osbakken, Mary& Green, Michael S.& Izzetoglu, Kurtulus. Near-Infrared Spectroscopy for the Evaluation of Anesthetic Depth. BioMed Research International. 2015. Vol. 2015, no. 2015, pp.1-11.
https://search.emarefa.net/detail/BIM-1057313
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1057313