A Technique for Removing Implant-Retained Denture: Direct Relining Complication

Joint Authors

Duran, İbrahim
Yilmaz, Betül
Ural, Çağrı

Source

Case Reports in Dentistry

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-06-23

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Dental

Abstract EN

The aim of this case report is to present a technique for removing the denture which locked to ball-attachment because of excessive hard relining resin material flows around the ball-attachment.

An alternative method was used in the present case.

A cylindrical resin was removed with a diamond bur at the level of matrix and by this way the matrix was removed safely.

The advantage of the presented method is that it may be extended to other clinical situations when facing a similar complication for implant supported dentures and also that the technique is simple and does not require special equipment.

American Psychological Association (APA)

Duran, İbrahim& Yilmaz, Betül& Ural, Çağrı. 2015. A Technique for Removing Implant-Retained Denture: Direct Relining Complication. Case Reports in Dentistry،Vol. 2015, no. 2015, pp.1-3.
https://search.emarefa.net/detail/BIM-1058225

Modern Language Association (MLA)

Duran, İbrahim…[et al.]. A Technique for Removing Implant-Retained Denture: Direct Relining Complication. Case Reports in Dentistry No. 2015 (2015), pp.1-3.
https://search.emarefa.net/detail/BIM-1058225

American Medical Association (AMA)

Duran, İbrahim& Yilmaz, Betül& Ural, Çağrı. A Technique for Removing Implant-Retained Denture: Direct Relining Complication. Case Reports in Dentistry. 2015. Vol. 2015, no. 2015, pp.1-3.
https://search.emarefa.net/detail/BIM-1058225

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1058225