Abstract EN

Traditional options in managing failed trabeculectomy (bleb needling, revision, additional incisional surgery and tube surgery) have a relatively high failure and complication rate.

The use of microinvasive glaucoma surgery (MIGS) has generally been reserved to mild to moderate glaucoma cases, proving good safety profiles but significant limitations in terms of efficacy.

We describe a patient who underwent MIGS (XEN Aquesys subconjunctival shunt implantation) after a prior failed trabeculectomy.

After the surgery, the IOP was well controlled but as the stent was close to an area of scarred conjunctiva of the previous trabeculectomy, it became partially exposed.

As a complete success was achieved, we decided to remove the conjunctiva over the exposed area and replace it by an amniotic membrane transplantation and a conjunctiva autograft.

Six months after surgery, the unmedicated IOP is still well controlled with complete visual acuity recovery.

American Psychological Association (APA)

Fea, Antonio& Cannizzo, Paola Maria Loredana& Consolandi, Giulia& Lavia, Carlo Alessandro& Pignata, Giulia& Grignolo, Federico M.. 2015. Managing Drawbacks in Unconventional Successful Glaucoma Surgery: A Case Report of Stent Exposure. Case Reports in Ophthalmological Medicine،Vol. 2015, no. 2015, pp.1-4.
https://search.emarefa.net/detail/BIM-1059413

Modern Language Association (MLA)

Fea, Antonio…[et al.]. Managing Drawbacks in Unconventional Successful Glaucoma Surgery: A Case Report of Stent Exposure. Case Reports in Ophthalmological Medicine No. 2015 (2015), pp.1-4.
https://search.emarefa.net/detail/BIM-1059413

American Medical Association (AMA)

Fea, Antonio& Cannizzo, Paola Maria Loredana& Consolandi, Giulia& Lavia, Carlo Alessandro& Pignata, Giulia& Grignolo, Federico M.. Managing Drawbacks in Unconventional Successful Glaucoma Surgery: A Case Report of Stent Exposure. Case Reports in Ophthalmological Medicine. 2015. Vol. 2015, no. 2015, pp.1-4.
https://search.emarefa.net/detail/BIM-1059413

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1059413