Arthroscopic Removal of a Wire Fragment from the Posterior Septum of the Knee following Tension Band Wiring of a Patellar Fracture

Joint Authors

Tamaki, Yasuaki
Nakayama, Takashi
Kita, Kenichiro
Miyatake, Katsutosi
Fujii, Koji
Takeda, Yoshitsugu
Kawasaki, Yoshiteru

Source

Case Reports in Orthopedics

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-02-09

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Medicine

Abstract EN

Tension band wiring with cerclage wiring is most widely used for treating displaced patellar fractures.

Although wire breakage is not uncommon, migration of a fragment of the broken wire is rare, especially migration into the knee joint.

We describe here a rare case of migration of a wire fragment into the posterior septum of the knee joint after fixation of a displaced patellar fracture with tension band wiring and cerclage wiring.

Although it was difficult to determine whether the wire fragment was located within or outside the knee joint from the preoperative plain radiographs or three-dimensional computed tomography (3D CT), we found it arthroscopically through the posterior transseptal portal with assistance of intraoperative fluoroscopy.

Surgeons who treat such cases should bear in mind the possibility that wire could be embedded in the posterior septum of the knee joint.

American Psychological Association (APA)

Tamaki, Yasuaki& Nakayama, Takashi& Kita, Kenichiro& Miyatake, Katsutosi& Kawasaki, Yoshiteru& Fujii, Koji…[et al.]. 2015. Arthroscopic Removal of a Wire Fragment from the Posterior Septum of the Knee following Tension Band Wiring of a Patellar Fracture. Case Reports in Orthopedics،Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1059554

Modern Language Association (MLA)

Tamaki, Yasuaki…[et al.]. Arthroscopic Removal of a Wire Fragment from the Posterior Septum of the Knee following Tension Band Wiring of a Patellar Fracture. Case Reports in Orthopedics No. 2015 (2015), pp.1-5.
https://search.emarefa.net/detail/BIM-1059554

American Medical Association (AMA)

Tamaki, Yasuaki& Nakayama, Takashi& Kita, Kenichiro& Miyatake, Katsutosi& Kawasaki, Yoshiteru& Fujii, Koji…[et al.]. Arthroscopic Removal of a Wire Fragment from the Posterior Septum of the Knee following Tension Band Wiring of a Patellar Fracture. Case Reports in Orthopedics. 2015. Vol. 2015, no. 2015, pp.1-5.
https://search.emarefa.net/detail/BIM-1059554

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1059554