Endoscopic Ex Vivo Evaluation of Bile Concentrations by Narrow Band Imaging: A Pilot Study

Joint Authors

Maselli, Roberta
Santi, Esperanza Grace
Yoshida, Akira
Inoue , Haruhiro
Sato, Hiroki
Ikeda, Haruo
Kudo, Shin-ei
Eleftheriadis, Nikolas
Onimaru, Manabu

Source

Gastroenterology Research and Practice

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-05-13

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Diseases

Abstract EN

Background.

Bile juice plays a major role in duodenogastroesophageal reflux (DGERD).

Several devices to directly measure the bile concentration have been proposed.

We aimed to ex-vivo evaluate the bile concentration by narrow band imaging (NBI).

Method.

From six surgical cholecystectomies, the content of the gallbladders was aspirated and the total biliary acid (TBA) concentration was evaluated.

2 mL was employed for serial twofold dilutions.

Each dilution was scoped.

Images on white light (WL) and NBI were captured and grouped accordingly to NBI-appearance and TBA-concentration.

Results.

Nondiluted bile had a TBA-concentration of 61965 ± 32989 μmol/L.

Final dilution (1 : 4096) had 1.16 μmol/L.

NBI and correspondent WL images were grouped into seven groups, and an NBI/Bile scale was created.

Conclusion.

The scale showed that not only NBI scale but also white light scale could be useful to predict the bile concentration.

This initial study shows that NBI has a potential role in the detection of DGERD and further investigation is warranted to distinguish the presence and the concentration of bile, especially at very low TBA concentrations.

American Psychological Association (APA)

Maselli, Roberta& Inoue , Haruhiro& Ikeda, Haruo& Onimaru, Manabu& Yoshida, Akira& Santi, Esperanza Grace…[et al.]. 2015. Endoscopic Ex Vivo Evaluation of Bile Concentrations by Narrow Band Imaging: A Pilot Study. Gastroenterology Research and Practice،Vol. 2015, no. 2015, pp.1-3.
https://search.emarefa.net/detail/BIM-1063968

Modern Language Association (MLA)

Maselli, Roberta…[et al.]. Endoscopic Ex Vivo Evaluation of Bile Concentrations by Narrow Band Imaging: A Pilot Study. Gastroenterology Research and Practice No. 2015 (2015), pp.1-3.
https://search.emarefa.net/detail/BIM-1063968

American Medical Association (AMA)

Maselli, Roberta& Inoue , Haruhiro& Ikeda, Haruo& Onimaru, Manabu& Yoshida, Akira& Santi, Esperanza Grace…[et al.]. Endoscopic Ex Vivo Evaluation of Bile Concentrations by Narrow Band Imaging: A Pilot Study. Gastroenterology Research and Practice. 2015. Vol. 2015, no. 2015, pp.1-3.
https://search.emarefa.net/detail/BIM-1063968

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1063968