Ultrasensitive NO2 Gas Sensor Based on Epitaxial Graphene

Joint Authors

Novikov, S.
Lebedeva, N.
Satrapinski, A.

Source

Journal of Sensors

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-01-29

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Civil Engineering

Abstract EN

We report about technology of fabrication and optimization of a gas sensor based on epitaxial graphene.

Optimized graphene/metal contact configuration exhibited low contact resistance.

Complementary annealing of graphene sensor after each gas exposure led to significant improvement in the sensing performance.

The response of the annealed sensor to the nitrogen dioxide (NO2) was tenfold higher than that of an as-fabricated graphene sensor.

NO2 concentration as low as 0.2 parts per billion (ppb) was easily detectable.

Devices have high signal-to-noise ratio.

The detection limit of the graphene sensor was estimated to be 0.6 ppt (parts per trillion).

The present technology with additional annealing improves the performance of the graphene based sensor and makes it suitable for the environmental nitrogen dioxide gas monitoring.

American Psychological Association (APA)

Novikov, S.& Lebedeva, N.& Satrapinski, A.. 2015. Ultrasensitive NO2 Gas Sensor Based on Epitaxial Graphene. Journal of Sensors،Vol. 2015, no. 2015, pp.1-7.
https://search.emarefa.net/detail/BIM-1070059

Modern Language Association (MLA)

Novikov, S.…[et al.]. Ultrasensitive NO2 Gas Sensor Based on Epitaxial Graphene. Journal of Sensors No. 2015 (2015), pp.1-7.
https://search.emarefa.net/detail/BIM-1070059

American Medical Association (AMA)

Novikov, S.& Lebedeva, N.& Satrapinski, A.. Ultrasensitive NO2 Gas Sensor Based on Epitaxial Graphene. Journal of Sensors. 2015. Vol. 2015, no. 2015, pp.1-7.
https://search.emarefa.net/detail/BIM-1070059

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1070059