SIMMER-III Analyses of Local Fuel-Coolant Interactions in a Simulated Molten Fuel Pool: Effect of Coolant Quantity

Joint Authors

Cheng, Songbai
Matsuba, Ken-ichi
Isozaki, Mikio
Kamiyama, Kenji
Tobita, Yoshiharu
Suzuki, T.

Source

Science and Technology of Nuclear Installations

Issue

Vol. 2015, Issue 2015 (31 Dec. 2015), pp.1-14, 14 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2015-01-14

Country of Publication

Egypt

No. of Pages

14

Abstract EN

Studies on local fuel-coolant interactions (FCI) in a molten pool are important for the analyses of severe accidents that could occur for sodium-cooled fast reactors (SFRs).

To clarify the mechanisms underlying this interaction, in recent years, several experimental tests, with comparatively larger difference in coolant volumes, were conducted at the Japan Atomic Energy Agency by delivering a given quantity of water into a molten pool formed with a low-melting-point alloy.

In this study, to further understand this interaction, interaction characteristics including the pressure buildup as well as mechanical energy release and its conversion efficiency are investigated using the SIMMER-III, an advanced fast reactor safety analysis code.

It is found that the SIMMER-III code not only reasonably simulates the transient pressure and temperature variations during local FCIs, but also supports the limited tendency of pressurization and resultant mechanical energy release as observed from experiments when the volume of water delivered into the pool increases.

The performed analyses also suggest that the most probable reason leading to such limited tendency should be primarily due to an isolation effect of vapor bubbles generated at the water-melt interface.

American Psychological Association (APA)

Cheng, Songbai& Matsuba, Ken-ichi& Isozaki, Mikio& Kamiyama, Kenji& Suzuki, T.& Tobita, Yoshiharu. 2015. SIMMER-III Analyses of Local Fuel-Coolant Interactions in a Simulated Molten Fuel Pool: Effect of Coolant Quantity. Science and Technology of Nuclear Installations،Vol. 2015, no. 2015, pp.1-14.
https://search.emarefa.net/detail/BIM-1077892

Modern Language Association (MLA)

Cheng, Songbai…[et al.]. SIMMER-III Analyses of Local Fuel-Coolant Interactions in a Simulated Molten Fuel Pool: Effect of Coolant Quantity. Science and Technology of Nuclear Installations No. 2015 (2015), pp.1-14.
https://search.emarefa.net/detail/BIM-1077892

American Medical Association (AMA)

Cheng, Songbai& Matsuba, Ken-ichi& Isozaki, Mikio& Kamiyama, Kenji& Suzuki, T.& Tobita, Yoshiharu. SIMMER-III Analyses of Local Fuel-Coolant Interactions in a Simulated Molten Fuel Pool: Effect of Coolant Quantity. Science and Technology of Nuclear Installations. 2015. Vol. 2015, no. 2015, pp.1-14.
https://search.emarefa.net/detail/BIM-1077892

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1077892