A Bioequivalence Test by the Direct Comparison of Concentration-versus-Time Curves Using Local Polynomial Smoothers

Joint Authors

Tian, Suyan
Chang, Howard H.
Orange, Dana
Gu, Jingkai
Suárez-Fariñas, Mayte

Source

Computational and Mathematical Methods in Medicine

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-12-05

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Medicine

Abstract EN

In order to test if two chemically or pharmaceutically equivalent products have the same efficacy and/or toxicity, a bioequivalence (BE) study is conducted.

The 80%/125% rule is the most commonly used criteria for BE and states that BE cannot be claimed unless the 90% CIs for the ratio of selected pharmacokinetics (PK) parameters of the tested to the reference drug are within 0.8 to 1.25.

Considering that estimates of these PK parameters are derived from the concentration-versus-time curves, a direct comparison between these curves motivates an alternative and more flexible approach to test BE.

Here, we propose to frame the BE test in terms of an equivalence of concentration-versus-time curves which are constructed using local polynomial smoother (LPS).

A metric is presented to quantify the distance between the curves and its 90% CIs are calculated via bootstrapping.

Then, we applied the proposed procedures to data from an animal study and found that BE between a generic drug and its brand name cannot be concluded, which was consistent with the results by applying the 80%/125% rule.

However, the proposed procedure has the advantage of testing only on a single metric, instead of all PK parameters.

American Psychological Association (APA)

Tian, Suyan& Chang, Howard H.& Orange, Dana& Gu, Jingkai& Suárez-Fariñas, Mayte. 2016. A Bioequivalence Test by the Direct Comparison of Concentration-versus-Time Curves Using Local Polynomial Smoothers. Computational and Mathematical Methods in Medicine،Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1100136

Modern Language Association (MLA)

Tian, Suyan…[et al.]. A Bioequivalence Test by the Direct Comparison of Concentration-versus-Time Curves Using Local Polynomial Smoothers. Computational and Mathematical Methods in Medicine No. 2016 (2016), pp.1-6.
https://search.emarefa.net/detail/BIM-1100136

American Medical Association (AMA)

Tian, Suyan& Chang, Howard H.& Orange, Dana& Gu, Jingkai& Suárez-Fariñas, Mayte. A Bioequivalence Test by the Direct Comparison of Concentration-versus-Time Curves Using Local Polynomial Smoothers. Computational and Mathematical Methods in Medicine. 2016. Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1100136

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1100136