An Unusual Trocar Site Hernia after Prostatectomy

Joint Authors

Schmocker, Ryan K.
Greenberg, Jacob A.

Source

Case Reports in Surgery

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-08-28

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Medicine

Abstract EN

Trocar site hernias are rare complications after laparoscopic surgery but most commonly occur at larger trocar sites placed at the umbilicus.

With increased utilization of the laparoscopic approach the incidence of trocar site hernia is increasing.

We report a case of a trocar site hernia following an otherwise uncomplicated robotic prostatectomy at a 12 mm right lower quadrant port.

The vermiform appendix was incarcerated within the trocar site hernia.

Subsequent appendectomy and primary repair of the hernia were performed without complication.

American Psychological Association (APA)

Schmocker, Ryan K.& Greenberg, Jacob A.. 2016. An Unusual Trocar Site Hernia after Prostatectomy. Case Reports in Surgery،Vol. 2016, no. 2016, pp.1-3.
https://search.emarefa.net/detail/BIM-1102736

Modern Language Association (MLA)

Schmocker, Ryan K.& Greenberg, Jacob A.. An Unusual Trocar Site Hernia after Prostatectomy. Case Reports in Surgery No. 2016 (2016), pp.1-3.
https://search.emarefa.net/detail/BIM-1102736

American Medical Association (AMA)

Schmocker, Ryan K.& Greenberg, Jacob A.. An Unusual Trocar Site Hernia after Prostatectomy. Case Reports in Surgery. 2016. Vol. 2016, no. 2016, pp.1-3.
https://search.emarefa.net/detail/BIM-1102736

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1102736