Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature

Joint Authors

Phan, Quang-Bao
Koutlidis, Nicolas
Duperron, Céline
Mourey, Eric
Michel, Frédéric
Cormier, Luc

Source

Case Reports in Urology

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-4, 4 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-03-30

Country of Publication

Egypt

No. of Pages

4

Main Subjects

Medicine

Abstract EN

Introduction.

We report a case of spontaneous rupture of a single testicular prosthesis in a patient who had undergone bilateral orchiectomy and silicone gel-filled prosthesis insertion.

The consequences of this rare event are discussed.

There is no management algorithm.

Case Presentation.

A 55-year-old man presented to our outpatient department with altered consistency in his right testicular prosthesis and a painful right hemiscrotum with no systemic symptoms thirty-three years after the implantation of the prosthesis.

We removed this implant without replacement, in accordance with the patient’s wishes.

Conclusion.

The long time between the implantation and the spontaneous rupture is remarkable and was never before described.

The removal of the prosthesis was straightforward and it would have been possible to implant a new prosthesis after taking into account the condition of the skin.

American Psychological Association (APA)

Phan, Quang-Bao& Koutlidis, Nicolas& Duperron, Céline& Mourey, Eric& Michel, Frédéric& Cormier, Luc. 2016. Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature. Case Reports in Urology،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1102957

Modern Language Association (MLA)

Phan, Quang-Bao…[et al.]. Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature. Case Reports in Urology No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1102957

American Medical Association (AMA)

Phan, Quang-Bao& Koutlidis, Nicolas& Duperron, Céline& Mourey, Eric& Michel, Frédéric& Cormier, Luc. Management of Testicular Silicone Gel-Filled Prosthesis Rupture: Case Report of a Rare Event and a Review of the Literature. Case Reports in Urology. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1102957