Adaptive Corrosion Protection System Using Continuous Corrosion Measurement, Parameter Extraction, and Corrective Loop

Joint Authors

Kaminska, Bozena
Patel, Jasbir N.
Chang, Andre
Shahbazbegian, Haleh

Source

International Journal of Corrosion

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-11, 11 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-03-17

Country of Publication

Egypt

No. of Pages

11

Main Subjects

Civil Engineering

Abstract EN

A simple current-sourced adaptive corrosion protection system (ACPS) along with a technology to extract the protection current from the Tafel plot is presented.

For reliable protection of the target metal, first, the Tafel plot of the target metal is obtained.

Subsequently, a novel technique proposed in this paper is used to extract the protection current from the Tafel plot.

This extracted protection current is fed to the target metal to protect the metal in the existing corrosive environment.

This three-part system is adaptively used to update the required protection current to effectively protect the target metal continuously.

All these functionalities are integrated in a stand-alone ACPS that effectively diagnoses the corrosion status and updates the protection parameters without any manual interaction or physical modification of the set-up to offer modularity, reliability, and cost saving.

To validate the technique, a laboratory scale system is realized and tested using various metal samples and various corrosive mediums.

Using the experimental system, A36 metal coupons are effectively protected with protection (inhibition) efficiency of 40–100 % in different corrosive mediums that can extend the life expectancy of the target metal from ~2 times to more than 100 times for the tested corrosive mediums.

American Psychological Association (APA)

Patel, Jasbir N.& Chang, Andre& Shahbazbegian, Haleh& Kaminska, Bozena. 2016. Adaptive Corrosion Protection System Using Continuous Corrosion Measurement, Parameter Extraction, and Corrective Loop. International Journal of Corrosion،Vol. 2016, no. 2016, pp.1-11.
https://search.emarefa.net/detail/BIM-1105501

Modern Language Association (MLA)

Patel, Jasbir N.…[et al.]. Adaptive Corrosion Protection System Using Continuous Corrosion Measurement, Parameter Extraction, and Corrective Loop. International Journal of Corrosion No. 2016 (2016), pp.1-11.
https://search.emarefa.net/detail/BIM-1105501

American Medical Association (AMA)

Patel, Jasbir N.& Chang, Andre& Shahbazbegian, Haleh& Kaminska, Bozena. Adaptive Corrosion Protection System Using Continuous Corrosion Measurement, Parameter Extraction, and Corrective Loop. International Journal of Corrosion. 2016. Vol. 2016, no. 2016, pp.1-11.
https://search.emarefa.net/detail/BIM-1105501

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1105501