Selective and Sensitive Detection of Cyanide Based on the Displacement Strategy Using a Water-Soluble Fluorescent Probe

Joint Authors

La, Ming
Hao, Yuanqiang
Wang, Zhaoyang
Han, Guo-Cheng
Qu, Lingbo

Source

Journal of Analytical Methods in Chemistry

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-01-05

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Chemistry

Abstract EN

A water-soluble fluorescent probe (C-GGH) was used for the highly sensitive and selective detection of cyanide (CN−) in aqueous media based on the displacement strategy.

Due to the presence of the recognition unit GGH (Gly-Gly-His), the probe C-GGH can coordinate with Cu2+ and consequently display ON-OFF type fluorescence response.

Furthermore, the in situ formed nonfluorescent C-GGH-Cu2+ complex can act as an effective OFF-ON type fluorescent probe for sensing CN− anion.

Due to the strong binding affinity of CN− to Cu2+, CN− can extract Cu2+ from C-GGH-Cu2+ complex, leading to the release of C-GGH and the recovery of fluorescent emission of the system.

The probe C-GGH-Cu2+ allowed detection of CN− in aqueous solution with a LOD (limit of detection) of 0.017 μmol/L which is much lower than the maximum contaminant level (1.9 μmol/L) for CN− in drinking water set by the WHO (World Health Organization).

The probe also displayed excellent specificity for CN− towards other anions, including F−, Cl−, Br−, I−, SCN−, PO43-, N3-, NO3-, AcO−, SO42-, and CO32-.

American Psychological Association (APA)

La, Ming& Hao, Yuanqiang& Wang, Zhaoyang& Han, Guo-Cheng& Qu, Lingbo. 2016. Selective and Sensitive Detection of Cyanide Based on the Displacement Strategy Using a Water-Soluble Fluorescent Probe. Journal of Analytical Methods in Chemistry،Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1107266

Modern Language Association (MLA)

La, Ming…[et al.]. Selective and Sensitive Detection of Cyanide Based on the Displacement Strategy Using a Water-Soluble Fluorescent Probe. Journal of Analytical Methods in Chemistry No. 2016 (2016), pp.1-6.
https://search.emarefa.net/detail/BIM-1107266

American Medical Association (AMA)

La, Ming& Hao, Yuanqiang& Wang, Zhaoyang& Han, Guo-Cheng& Qu, Lingbo. Selective and Sensitive Detection of Cyanide Based on the Displacement Strategy Using a Water-Soluble Fluorescent Probe. Journal of Analytical Methods in Chemistry. 2016. Vol. 2016, no. 2016, pp.1-6.
https://search.emarefa.net/detail/BIM-1107266

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID