A Model for Analyzing a Five-Phase Fractional-Slot Permanent Magnet Tubular Linear Motor with Modified Winding Function Approach

Joint Authors

Zhang, Bo
Qi, Rong
Lin, Hui
Mwaniki, Julius

Source

Journal of Electrical and Computer Engineering

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-13, 13 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-10-27

Country of Publication

Egypt

No. of Pages

13

Main Subjects

Information Technology and Computer Science

Abstract EN

This paper presents a model for analyzing a five-phase fractional-slot permanent magnet tubular linear motor (FSPMTLM) with the modified winding function approach (MWFA).

MWFA is a fast modeling method and it gives deep insight into the calculations of the following parameters: air-gap magnetic field, inductances, flux linkages, and detent force, which are essential in modeling the motor.

First, using a magnetic circuit model, the air-gap magnetic density is computed from stator magnetomotive force (MMF), flux barrier, and mover geometry.

Second, the inductances, flux linkages, and detent force are analytically calculated using modified winding function and the air-gap magnetic density.

Finally, a model has been established with the five-phase Park transformation and simulated.

The calculations of detent force reveal that the end-effect force is the main component of the detent force.

This is also proven by finite element analysis on the motor.

The accuracy of the model is validated by comparing with the results obtained using semianalytical method (SAM) and measurements to analyze the motor’s transient characteristics.

In addition, the proposed method requires less computation time.

American Psychological Association (APA)

Zhang, Bo& Qi, Rong& Lin, Hui& Mwaniki, Julius. 2016. A Model for Analyzing a Five-Phase Fractional-Slot Permanent Magnet Tubular Linear Motor with Modified Winding Function Approach. Journal of Electrical and Computer Engineering،Vol. 2016, no. 2016, pp.1-13.
https://search.emarefa.net/detail/BIM-1108440

Modern Language Association (MLA)

Zhang, Bo…[et al.]. A Model for Analyzing a Five-Phase Fractional-Slot Permanent Magnet Tubular Linear Motor with Modified Winding Function Approach. Journal of Electrical and Computer Engineering No. 2016 (2016), pp.1-13.
https://search.emarefa.net/detail/BIM-1108440

American Medical Association (AMA)

Zhang, Bo& Qi, Rong& Lin, Hui& Mwaniki, Julius. A Model for Analyzing a Five-Phase Fractional-Slot Permanent Magnet Tubular Linear Motor with Modified Winding Function Approach. Journal of Electrical and Computer Engineering. 2016. Vol. 2016, no. 2016, pp.1-13.
https://search.emarefa.net/detail/BIM-1108440

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1108440