Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses

Joint Authors

Unsal, Ugur
Baser, Gonen

Source

Journal of Ophthalmology

Issue

Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-4, 4 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2016-06-01

Country of Publication

Egypt

No. of Pages

4

Main Subjects

Medicine

Abstract EN

Purpose.

To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted.

Methods.

41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed.

Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later.

Results.

The corrected and uncorrected distance visual acuity were the same between both groups (p=0.50 and p=0.509, resp.).

The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p=0.049, p=0.005, and p=0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p=0.001).

The patient satisfactions of both groups were similar.

Conclusion.

The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading).

American Psychological Association (APA)

Unsal, Ugur& Baser, Gonen. 2016. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses. Journal of Ophthalmology،Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109833

Modern Language Association (MLA)

Unsal, Ugur& Baser, Gonen. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses. Journal of Ophthalmology No. 2016 (2016), pp.1-4.
https://search.emarefa.net/detail/BIM-1109833

American Medical Association (AMA)

Unsal, Ugur& Baser, Gonen. Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses. Journal of Ophthalmology. 2016. Vol. 2016, no. 2016, pp.1-4.
https://search.emarefa.net/detail/BIM-1109833

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1109833