Is Low Serum Vitamin D Associated with Early Dental Implant Failure? A Retrospective Evaluation on 1625 Implants Placed in 822 Patients
Joint Authors
Mortellaro, Carmen
Mangano, Francesco Guido
Mangano, Natale
Mangano, Carlo
Source
Issue
Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-7, 7 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2016-09-22
Country of Publication
Egypt
No. of Pages
7
Main Subjects
Abstract EN
Aim.
To investigate whether there is a correlation between early dental implant failure and low serum levels of vitamin D.
Methods.
All patients treated with dental implants in a single centre, in the period 2003–2015, were considered for enrollment in this study.
The main outcome was early implant failure.
The influence of patient-related variables on implant survival was calculated using the Chi-square test.
Results.
822 patients treated with 1625 implants were selected for this study; 27 early failures (3.2%) were recorded.
There was no link between gender, age, smoking, history of periodontitis, and an increased incidence of early failures.
Statistical analysis reported 9 early failures (2.2%) in patients with serum levels of vitamin D > 30 ng/mL, 16 early failures (3.9%) in patients with levels between 10 and 30 ng/mL, and 2 early failures (9.0%) in patients with levels <10 ng/mL.
Although there was an increasing trend in the incidence of early implant failures with the worsening of vitamin D deficiency, the difference between these 3 groups was not statistically significant ( P = 0.15 ).
Conclusions.
This study failed in proving an effective link between low serum levels of vitamin D and an increased risk of early implant failure.
Further studies are needed to investigate this topic.
American Psychological Association (APA)
Mangano, Francesco Guido& Mortellaro, Carmen& Mangano, Natale& Mangano, Carlo. 2016. Is Low Serum Vitamin D Associated with Early Dental Implant Failure? A Retrospective Evaluation on 1625 Implants Placed in 822 Patients. Mediators of Inflammation،Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1111097
Modern Language Association (MLA)
Mangano, Francesco Guido…[et al.]. Is Low Serum Vitamin D Associated with Early Dental Implant Failure? A Retrospective Evaluation on 1625 Implants Placed in 822 Patients. Mediators of Inflammation No. 2016 (2016), pp.1-7.
https://search.emarefa.net/detail/BIM-1111097
American Medical Association (AMA)
Mangano, Francesco Guido& Mortellaro, Carmen& Mangano, Natale& Mangano, Carlo. Is Low Serum Vitamin D Associated with Early Dental Implant Failure? A Retrospective Evaluation on 1625 Implants Placed in 822 Patients. Mediators of Inflammation. 2016. Vol. 2016, no. 2016, pp.1-7.
https://search.emarefa.net/detail/BIM-1111097
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID