Removal of chrome and zinc from industrial wastewater using electrical precipitation and bentonite clays

Other Title(s)

إزالة الكروم و الزنك من المياة الصناعية باستخدام الترسيب الكهربائي و أطيان الينتونايت

Source

Journal of Engineering and Sustainable Development

Issue

Vol. 23, Issue 1 (31 Jan. 2019), pp.93-102, 10 p.

Publisher

al-Mustansyriah University College of Engineering

Publication Date

2019-01-31

Country of Publication

Iraq

No. of Pages

10

Main Subjects

Chemistry

Topics

Abstract EN

This study deals with removal of (Cr and Zn) from industrial wastewater resulted from production processes in the State Company of Electrical Industries (S.

C.

E.

I.

).

The removal process of these metals includes two stages; the first stage is the electrical precipitation of Cr and Zn metals, where Cr concentrations before and after performing this stage are 262 ppm and 26.6 ppm, respectively, while it is 1865 ppm and 45ppm for Zn.

The second stage includes treatment with bentonite clay to remove the remaining concentrations of heavy metals in industrial wastewater to be within Iraqi standard specification for discharging in to river.

Concentrations are < 0.1 ppm and < 1.0 ppm after applying this stage.

These processes are suggested to be an alternative method to that in the State Company of Electrical Industries which uses the chemical precipitation that produce wastes with high concentrations of chrome and zinc, which stored in containers until discarded.

from industrial wastewater resulted from production processes in the State Company of Electrical Industries (S.

C.

E.

I.

).

The removal process of these metals includes two stages; the first stage is the electrical precipitation of Cr and Zn metals, where Cr concentrations before and after performing this stage are 262 ppm and 26.6 ppm, respectively, while it is 1865 ppm and 45ppm for Zn.

The second stage includes treatment with bentonite clay to remove the remaining concentrations of heavy metals in industrial wastewater to be within Iraqi standard specification for discharging in to river.

Concentrations are < 0.1 ppm and < 1.0 ppm after applying this stage.

These processes are suggested to be an alternative method to that in the State Company of Electrical Industries which uses the chemical precipitation that produce wastes with high concentrations of chrome and zinc, which stored in containers until discarded.

American Psychological Association (APA)

Abd Allah, Walid Rashid. 2019. Removal of chrome and zinc from industrial wastewater using electrical precipitation and bentonite clays. Journal of Engineering and Sustainable Development،Vol. 23, no. 1, pp.93-102.
https://search.emarefa.net/detail/BIM-1113838

Modern Language Association (MLA)

Abd Allah, Walid Rashid. Removal of chrome and zinc from industrial wastewater using electrical precipitation and bentonite clays. Journal of Engineering and Sustainable Development Vol. 23, no. 1 (Jan. 2019), pp.93-102.
https://search.emarefa.net/detail/BIM-1113838

American Medical Association (AMA)

Abd Allah, Walid Rashid. Removal of chrome and zinc from industrial wastewater using electrical precipitation and bentonite clays. Journal of Engineering and Sustainable Development. 2019. Vol. 23, no. 1, pp.93-102.
https://search.emarefa.net/detail/BIM-1113838

Data Type

Journal Articles

Language

English

Notes

-

Record ID

BIM-1113838