On the Reliability and Repeatability of Surface Electromyography Factorization by Muscle Synergies in Daily Life Activities

Joint Authors

Del Prete, Zaccaria
Rossi, Stefano
Taborri, Juri
Palermo, Eduardo

Source

Applied Bionics and Biomechanics

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-15, 15 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-11-22

Country of Publication

Egypt

No. of Pages

15

Main Subjects

Biology

Abstract EN

Muscle synergy theory is a new appealing approach for different research fields.

This study is aimed at evaluating the robustness of EMG reconstruction via muscle synergies and the repeatability of muscle synergy parameters as potential neurophysiological indices.

Eight healthy subjects performed walking, stepping, running, and ascending and descending stairs’ trials for five repetitions in three sessions.

Twelve muscles of the dominant leg were analyzed.

The “nonnegative matrix factorization” and “variability account for” were used to extract muscle synergies and to assess EMG goodness reconstruction, respectively.

Intraclass correlation was used to quantify methodology reliability.

Cosine similarity and coefficient of determination assessed the repeatability of the muscle synergy vectors and the temporal activity patterns, respectively.

A 4-synergy model was selected for EMG signal factorization.

Intraclass correlation was excellent for the overall reconstruction, while it ranged from fair to excellent for single muscles.

The EMG reconstruction was found repeatable across sessions and subjects.

Considering the selection of neurophysiological indices, the number of synergies was not repeatable neither within nor between subjects.

Conversely, the cosine similarity and coefficient of determination values allow considering the muscle synergy vectors and the temporal activity patterns as potential neurophysiological indices due to their similarity both within and between subjects.

More specifically, some synergies in the 4-synergy model reveal themselves as more repeatable than others, suggesting focusing on them when seeking at the neurophysiological index identification.

American Psychological Association (APA)

Taborri, Juri& Palermo, Eduardo& Del Prete, Zaccaria& Rossi, Stefano. 2018. On the Reliability and Repeatability of Surface Electromyography Factorization by Muscle Synergies in Daily Life Activities. Applied Bionics and Biomechanics،Vol. 2018, no. 2018, pp.1-15.
https://search.emarefa.net/detail/BIM-1114699

Modern Language Association (MLA)

Taborri, Juri…[et al.]. On the Reliability and Repeatability of Surface Electromyography Factorization by Muscle Synergies in Daily Life Activities. Applied Bionics and Biomechanics No. 2018 (2018), pp.1-15.
https://search.emarefa.net/detail/BIM-1114699

American Medical Association (AMA)

Taborri, Juri& Palermo, Eduardo& Del Prete, Zaccaria& Rossi, Stefano. On the Reliability and Repeatability of Surface Electromyography Factorization by Muscle Synergies in Daily Life Activities. Applied Bionics and Biomechanics. 2018. Vol. 2018, no. 2018, pp.1-15.
https://search.emarefa.net/detail/BIM-1114699

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1114699