Comparison of Proposed Modified and Original Sequential Organ Failure Assessment Scores in Predicting ICU Mortality: A Prospective, Observational, Follow-Up Study
Joint Authors
Gholipour Baradari, Afshin
Firouzian, Abolfazl
Daneshiyan, Maryam
Aarabi, Mohsen
Talebiyan Kiakolaye, Yaser
Nouraei, Seyed Mahmood
Zamani Kiasari, Alieh
Habibi, Mohammad Reza
Emami Zeydi, Amir
Sadeghi, Faegheh
Sharifi, Hassan
Source
Issue
Vol. 2016, Issue 2016 (31 Dec. 2016), pp.1-5, 5 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2016-12-25
Country of Publication
Egypt
No. of Pages
5
Main Subjects
Abstract EN
Background.
The sequential organ failure assessment (SOFA) score has been recommended to triage critically ill patients in the intensive care unit (ICU).
This study aimed to compare the performance of our proposed MSOFA and original SOFA scores in predicting ICU mortality.
Methods.
This prospective observational study was conducted on 250 patients admitted to the ICU.
Both tools scores were calculated at the beginning, 24 hours of ICU admission, and 48 hours of ICU admission.
Diagnostic odds ratio and receiver operating characteristic (ROC) curve were used to compare the two scores.
Results.
MSOFA and SOFA predicted mortality similarly with an area under the ROC curve of 0.837, 0.992, and 0.977 for MSOFA 1, MSOFA 2, and MSOFA 3, respectively, and 0.857, 0.988, and 0.988 for SOFA 1, SOFA 2, and SOFA 3, respectively.
The sensitivity and specificity of MSOFA 1 in cut-off point 8 were 82.9% and 68.4%, respectively, MSOFA 2 in cut-off point 9.5 were 94.7% and 97.1%, respectively, and MSOFA 3 in cut-off point of 9.3 were 97.4% and 93.1%, respectively.
There was a significant positive correlation between the MSOFA 1 and the SOFA 1 (r: 0.942), 24 hours (r: 0.972), and 48 hours (r: 0.960).
Conclusion.
The proposed MSOFA and the SOFA scores had high diagnostic accuracy, sensitivity, and specificity for predicting mortality.
American Psychological Association (APA)
Gholipour Baradari, Afshin& Sharifi, Hassan& Firouzian, Abolfazl& Daneshiyan, Maryam& Aarabi, Mohsen& Talebiyan Kiakolaye, Yaser…[et al.]. 2016. Comparison of Proposed Modified and Original Sequential Organ Failure Assessment Scores in Predicting ICU Mortality: A Prospective, Observational, Follow-Up Study. Scientifica،Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1117873
Modern Language Association (MLA)
Gholipour Baradari, Afshin…[et al.]. Comparison of Proposed Modified and Original Sequential Organ Failure Assessment Scores in Predicting ICU Mortality: A Prospective, Observational, Follow-Up Study. Scientifica No. 2016 (2016), pp.1-5.
https://search.emarefa.net/detail/BIM-1117873
American Medical Association (AMA)
Gholipour Baradari, Afshin& Sharifi, Hassan& Firouzian, Abolfazl& Daneshiyan, Maryam& Aarabi, Mohsen& Talebiyan Kiakolaye, Yaser…[et al.]. Comparison of Proposed Modified and Original Sequential Organ Failure Assessment Scores in Predicting ICU Mortality: A Prospective, Observational, Follow-Up Study. Scientifica. 2016. Vol. 2016, no. 2016, pp.1-5.
https://search.emarefa.net/detail/BIM-1117873
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1117873