Simultaneous Determination of Zn(II)‎, Cd(II)‎, Pb(II)‎, and Cu(II)‎ Using Differential Pulse Anodic Stripping Voltammetry at a Bismuth Film-Modified Electrode

Joint Authors

Hai Phong, Nguyen
Thanh, Nguyen Mau
Van Hop, Nguyen
Luyen, Nguyen Dinh
Tam Toan, Tran Thanh

Source

Advances in Materials Science and Engineering

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-11, 11 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-04-17

Country of Publication

Egypt

No. of Pages

11

Abstract EN

The simultaneous electrochemical determination of Zn(II), Cd(II), Pb(II), and Cu(II) in the aqueous solution has been developed on the basis of the bismuth film glassy carbon electrode (GCE) using differential pulse anodic stripping voltammetry (DP-ASV).

The bismuth film electrode (BiFE) was prepared by adding 500 ppb bismuth(III) directly to the sample solution and simultaneously depositing bismuth and the metal analytes on GCE.

The optimal operational parameters, namely, accumulation potential (–1.6 V), accumulation time (110 s), pulsed amplitude (0.07 V), and scan rate (0.021 V·s−1), were found using a Box–Behnken design.

Under the optimum conditions, a linear relationship exists between the current and the concentration of Zn(II), Cd(II), Pb(II), and Cu(II) in the range between 5.0 ppb and 110.0 ppb with the detection limits of 1.07 for Zn(II), 0.93 ppb for Cd(II), 0.65 ppb for Pb(II), and 0.94 ppb for Cu(II) calculated on the basis of a signal-to-noise ratio equal to 3 (S/N = 3).

The interference experiments show that Co(II), Ni(II), and Fe(III) have a little influence on the DP-ASV signals of Zn(II), Cd(II), Pb(II), and Cu(II).

In addition, a high reproducibility was indicated from small relative standard deviations (1.03%, 1.74%, 1.32%, and 4.74%) for 25 repeated measurements of 15 ppb copper, lead, cadmium, and zinc solutions.

BiFE was successfully applied to determine Zn(II), Cd(II), Pb(II), and Cu(II) in river samples, and the results are in a good agreement with those determined with graphite furnace atomic absorption spectrometry (GF-AAS).

American Psychological Association (APA)

Thanh, Nguyen Mau& Van Hop, Nguyen& Luyen, Nguyen Dinh& Hai Phong, Nguyen& Tam Toan, Tran Thanh. 2019. Simultaneous Determination of Zn(II), Cd(II), Pb(II), and Cu(II) Using Differential Pulse Anodic Stripping Voltammetry at a Bismuth Film-Modified Electrode. Advances in Materials Science and Engineering،Vol. 2019, no. 2019, pp.1-11.
https://search.emarefa.net/detail/BIM-1119357

Modern Language Association (MLA)

Thanh, Nguyen Mau…[et al.]. Simultaneous Determination of Zn(II), Cd(II), Pb(II), and Cu(II) Using Differential Pulse Anodic Stripping Voltammetry at a Bismuth Film-Modified Electrode. Advances in Materials Science and Engineering No. 2019 (2019), pp.1-11.
https://search.emarefa.net/detail/BIM-1119357

American Medical Association (AMA)

Thanh, Nguyen Mau& Van Hop, Nguyen& Luyen, Nguyen Dinh& Hai Phong, Nguyen& Tam Toan, Tran Thanh. Simultaneous Determination of Zn(II), Cd(II), Pb(II), and Cu(II) Using Differential Pulse Anodic Stripping Voltammetry at a Bismuth Film-Modified Electrode. Advances in Materials Science and Engineering. 2019. Vol. 2019, no. 2019, pp.1-11.
https://search.emarefa.net/detail/BIM-1119357

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1119357