Abstract EN

This paper presented temperature scanning tests of the viscoelastic materials firstly.

The temperature scanning tests were carried out by a Rheogel-E4000DMA analyzer and the results showed the modulus and loss factor of viscoelastic damping material.

Secondly, the full-scale laboratory test of the “5+4” VDW was carried out.

The test was conducted on an electrohydraulic servo tester.

A new shear loading mode in the transverse direction was proposed for the VDW.

And the maximum damping force, the storage stiffness, the loss stiffness, equivalent damping coefficient, the shear storage modulus, the shear loss modulus, and the loss factor were discussed in the text.

American Psychological Association (APA)

Xu, Junhong& Li, Aiqun. 2015. Mechanical Properties of a “5+4” Viscoelastic Damping Wall Based on Full-Scale Laboratory Tests. Shock and Vibration،Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1119574

Modern Language Association (MLA)

Xu, Junhong& Li, Aiqun. Mechanical Properties of a “5+4” Viscoelastic Damping Wall Based on Full-Scale Laboratory Tests. Shock and Vibration No. 2016 (2016), pp.1-10.
https://search.emarefa.net/detail/BIM-1119574

American Medical Association (AMA)

Xu, Junhong& Li, Aiqun. Mechanical Properties of a “5+4” Viscoelastic Damping Wall Based on Full-Scale Laboratory Tests. Shock and Vibration. 2015. Vol. 2016, no. 2016, pp.1-10.
https://search.emarefa.net/detail/BIM-1119574

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1119574