![](/images/graphics-bg.png)
Three-Month Retention of Basic Life Support with an Automated External Defibrillator Using a Two-Stage versus Four-Stage Teaching Technique
Joint Authors
Bomholt, Katrine Bjørnshave
Krogh, Lise Qvirin
Bomholt, Svend Rosendahl
Nebsbjerg, Mette Amalie
Thim, Troels
Løfgren, Bo
Source
Issue
Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-5, 5 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2019-07-16
Country of Publication
Egypt
No. of Pages
5
Main Subjects
Abstract EN
Introduction.
Resuscitation training increases bystander’s ability to perform basic life support (BLS) with an automated external defibrillator (AED) immediately after training.
However, several studies indicate that resuscitation skills decay rapidly.
Methods.
This study evaluates retention of BLS/AED skills three months after an initial study comparing acquisition of BLS/AED skills among laypersons immediately after training with a two-stage versus four-stage teaching technique.
Results.
There was no difference in retention of BLS/AED skills (pass rate 10.8% versus 10.9%, respectively, p=1) three months after training.
Total average number of skills adequately performed (of 17) was 13.3 versus 13.7 among laypersons trained with a two-stage and a four-stage technique, respectively.
No difference was found in quality of chest compressions and rescue breaths between the two groups.
Conclusion.
Three months after training, this study found no difference in retention of BLS/AED skills among laypersons taught using a two-stage compared to a four-stage teaching technique.
American Psychological Association (APA)
Bomholt, Katrine Bjørnshave& Krogh, Lise Qvirin& Bomholt, Svend Rosendahl& Nebsbjerg, Mette Amalie& Thim, Troels& Løfgren, Bo. 2019. Three-Month Retention of Basic Life Support with an Automated External Defibrillator Using a Two-Stage versus Four-Stage Teaching Technique. BioMed Research International،Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1123316
Modern Language Association (MLA)
Bomholt, Katrine Bjørnshave…[et al.]. Three-Month Retention of Basic Life Support with an Automated External Defibrillator Using a Two-Stage versus Four-Stage Teaching Technique. BioMed Research International No. 2019 (2019), pp.1-5.
https://search.emarefa.net/detail/BIM-1123316
American Medical Association (AMA)
Bomholt, Katrine Bjørnshave& Krogh, Lise Qvirin& Bomholt, Svend Rosendahl& Nebsbjerg, Mette Amalie& Thim, Troels& Løfgren, Bo. Three-Month Retention of Basic Life Support with an Automated External Defibrillator Using a Two-Stage versus Four-Stage Teaching Technique. BioMed Research International. 2019. Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1123316
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1123316