Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement

Joint Authors

Ott, Ilka
Schunkert, Heribert
Kastrati, Adnan
Shivaraju, Anupama
Thilo, Christian
Sawlani, Neal
von Scheidt, Wolfgang
Kasel, Albert Markus

Source

BioMed Research International

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-04-30

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Medicine

Abstract EN

Objectives.

The aim of this study is to assess the feasibility and clinical outcome of transcatheter aortic valve replacement (TAVR) using aortic valve predilatation (AVPD) with a small, nonocclusive balloon.

Background.

Balloon aortic valvuloplasty (BAV) under rapid pacing is generally performed in TAVR to ensure the passage and sufficient deployment of the prosthesis in the stenotic AV.

BAV may cause serious complications, such as left ventricular stunning or cerebrovascular embolism.

Methods.

A cohort of 50 consecutive patients with severe aortic stenosis underwent transfemoral TAVR with the Edwards Sapien 3-heart valve.

All patients underwent AVPD with a small, nonocclusive balloon (12 × 60 or 14 × 60 mm) without rapid pacing.

Procedural data and clinical outcomes were analyzed.

Results.

The mean age of the cohort was 81±6 years and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 13±9.

Crossing the AV and prosthesis implantation was successful in all cases.

The postprocedural mean AV gradient was 12±5 mmHg.

There were no cases of aortic regurgitation ≥ grade 2.

No periprocedural stroke occurred.

One patient (2%) with chronic atrial fibrillation displayed a transient Wernicke aphasia occurring more than 24 hours after TAVR.

Mortality was 0% at 30 days after procedure.

Conclusion.

In TAVR, AVPD with a small, nonocclusive balloon can be safely performed.

By avoiding rapid pacing, this technique may be a valid alternative to traditional BAV.

Whether or not the use of APVD without rapid pacing translates into less periprocedural complications needs to be assessed in future studies.

American Psychological Association (APA)

Shivaraju, Anupama& Thilo, Christian& Sawlani, Neal& Ott, Ilka& Schunkert, Heribert& von Scheidt, Wolfgang…[et al.]. 2018. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement. BioMed Research International،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1124149

Modern Language Association (MLA)

Shivaraju, Anupama…[et al.]. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement. BioMed Research International No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1124149

American Medical Association (AMA)

Shivaraju, Anupama& Thilo, Christian& Sawlani, Neal& Ott, Ilka& Schunkert, Heribert& von Scheidt, Wolfgang…[et al.]. Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1124149

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1124149