Accuracy of Leg Length and Offset Restoration in Femoral Pinless Navigation Compared to Navigation Using a Fixed Pin during Total Hip Arthroplasty

Joint Authors

Grifka, Joachim
Weber, Markus
Thieme, Max
Kaiser, Moritz
Völlner, Florian
Worlicek, Michael
Craiovan, Benjamin
Renkawitz, Tobias

Source

BioMed Research International

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-06-25

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Medicine

Abstract EN

Equalization of biomechanical differences is a major goal in total hip arthroplasty (THA).

In the current study we compared the accuracy of restoring leg length and offset using imageless navigation with an osseous fixed pin to a femoral pinless device in 97 minimally invasive THAs through an anterolateral approach in the lateral decubitus position.

Leg length and offset differences were evaluated on magnification-corrected radiographs by a blinded observer.

A postoperative mean difference of -0.9 mm (95% CI -2.8 mm to 1.1 mm, p = 0.38) between pinless navigation and navigation with a fixed pin was observed for leg length and that of -2.4 mm (95% CI -3.9 mm to -0.9 mm, p = 0.002) was observed for offset, respectively.

The number of patients with a residual difference below 5 mm after THA was higher if using a fixed pin than in pinless navigation for both leg length (98.2%, 54/55 to 50.0%, 21/42, p < 0.001) and offset (100.0%, 55/55 to 71.4%, 30/42, p < 0.001).

Imageless navigation is a feasible method in intraoperative control of leg length and offset in minimally invasive THA.

The use of pins fixed to the bone has a higher precision than pinless devices.

This trial is registered with DRKS00000739.

American Psychological Association (APA)

Weber, Markus& Thieme, Max& Kaiser, Moritz& Völlner, Florian& Worlicek, Michael& Craiovan, Benjamin…[et al.]. 2018. Accuracy of Leg Length and Offset Restoration in Femoral Pinless Navigation Compared to Navigation Using a Fixed Pin during Total Hip Arthroplasty. BioMed Research International،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1124526

Modern Language Association (MLA)

Weber, Markus…[et al.]. Accuracy of Leg Length and Offset Restoration in Femoral Pinless Navigation Compared to Navigation Using a Fixed Pin during Total Hip Arthroplasty. BioMed Research International No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1124526

American Medical Association (AMA)

Weber, Markus& Thieme, Max& Kaiser, Moritz& Völlner, Florian& Worlicek, Michael& Craiovan, Benjamin…[et al.]. Accuracy of Leg Length and Offset Restoration in Femoral Pinless Navigation Compared to Navigation Using a Fixed Pin during Total Hip Arthroplasty. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1124526

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1124526