Kirschner Wire Temporary Intramedullary Fixation Combined with a Locking Anatomical Plate versus a Reconstruction Plate in the Treatment of Comminuted Clavicular Fractures: A Retrospective Study

Joint Authors

Xu, Dan-Feng
Xie, Jianxin
Zheng, Xiaofei
Zhou, Mingdi
Ouyang, Wei
Zhang, Tao
Lu, Lei

Source

BioMed Research International

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-12-23

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Medicine

Abstract EN

We investigate the clinical efficacy of Kirschner wire temporary intramedullary fixation combined with a locking anatomical plate for the treatment of comminuted clavicular fractures.

We retrospectively studied 112 patients [80 (71%) men] treated between February 2007 and February 2014.

The patients were allocated to treatment with Kirschner wire temporary intramedullary fixation combined with a locking anatomical plate [minimally invasive group (GM)] or a reconstruction plate [traditional group (GT)].

The 112 patients were followed up for 12–48 months (mean, 14 months).

The operation time was significantly shorter in GM than in GT.

Intraoperative blood loss was significantly less in GM than in GT.

The total incision length was significantly shorter and the visual analog scale pain score 24 h after surgery was significantly lower in GM than in GT.

Fracture healing time was significantly shorter and the complication rate was significantly lower in GM than in GT.

No significant difference in shoulder function score was observed between groups.

We recommend Kirschner wire temporary intramedullary fixation combined with a locking anatomical plate as the treatment of choice for comminuted clavicular fractures because of the shorter operation time, lesser intraoperative blood loss, easier reduction of the operation, quicker fracture healing, and lower postoperative complication rate.

American Psychological Association (APA)

Xie, Jianxin& Xu, Dan-Feng& Zheng, Xiaofei& Zhou, Mingdi& Ouyang, Wei& Zhang, Tao…[et al.]. 2018. Kirschner Wire Temporary Intramedullary Fixation Combined with a Locking Anatomical Plate versus a Reconstruction Plate in the Treatment of Comminuted Clavicular Fractures: A Retrospective Study. BioMed Research International،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1127028

Modern Language Association (MLA)

Xie, Jianxin…[et al.]. Kirschner Wire Temporary Intramedullary Fixation Combined with a Locking Anatomical Plate versus a Reconstruction Plate in the Treatment of Comminuted Clavicular Fractures: A Retrospective Study. BioMed Research International No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1127028

American Medical Association (AMA)

Xie, Jianxin& Xu, Dan-Feng& Zheng, Xiaofei& Zhou, Mingdi& Ouyang, Wei& Zhang, Tao…[et al.]. Kirschner Wire Temporary Intramedullary Fixation Combined with a Locking Anatomical Plate versus a Reconstruction Plate in the Treatment of Comminuted Clavicular Fractures: A Retrospective Study. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1127028

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1127028