![](/images/graphics-bg.png)
Comparing Different Recording Lengths of Dynamic Cerebral Autoregulation: 5 versus 10 Minutes
Joint Authors
Chi, Nai-Fang
Wang, Cheng-Yen
Chan, Lung
Hu, Han-Hwa
Source
Issue
Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-6, 6 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2018-01-31
Country of Publication
Egypt
No. of Pages
6
Main Subjects
Abstract EN
We compared the dynamic cerebral autoregulation (dCA) indices between 5- and 10-minute data lengths by analyzing 37 patients with ischemic stroke and 51 controls in this study.
Correlation coefficient (Mx) and transfer function analysis were applied for dCA analysis.
Mx and phase shift in all frequency bands were not significantly different between 5- and 10-minute recordings [mean difference: Mx = 0.02; phase shift of very low frequency (0.02–0.07 Hz) = 0.3°, low frequency (0.07–0.20 Hz) = 0.6°, and high frequency (0.20–0.50 Hz) = 0.1°].
However, the gains in all frequency bands of a 5-minute recording were slightly but significantly higher than those of a 10-minute recording (mean difference of gain: very low frequency = 0.05 cm/s/mmHg, low frequency = 0.11 cm/s/mmHg, and high frequency = 0.14 cm/s/mmHg).
The intraclass correlation coefficients between all dCA indices of 5- and 10-minute recordings were favorable, especially in Mx (0.93), phase shift in very low frequency (0.87), and gain in very low frequency (0.94).
The areas under the receiver operating characteristic curve for stroke diagnosis between 5- and 10-minute recordings were not different.
We concluded that dCA assessed by using a 5-minute recording is not significantly different from that using a 10-minute recording in the clinical application.
American Psychological Association (APA)
Chi, Nai-Fang& Wang, Cheng-Yen& Chan, Lung& Hu, Han-Hwa. 2018. Comparing Different Recording Lengths of Dynamic Cerebral Autoregulation: 5 versus 10 Minutes. BioMed Research International،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1128699
Modern Language Association (MLA)
Chi, Nai-Fang…[et al.]. Comparing Different Recording Lengths of Dynamic Cerebral Autoregulation: 5 versus 10 Minutes. BioMed Research International No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1128699
American Medical Association (AMA)
Chi, Nai-Fang& Wang, Cheng-Yen& Chan, Lung& Hu, Han-Hwa. Comparing Different Recording Lengths of Dynamic Cerebral Autoregulation: 5 versus 10 Minutes. BioMed Research International. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1128699
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID