Corrosion Localization Analysis in T-Shape Pipe Junction Based on Multielectrode Current Measurements

Author

Vasyliev, Georgii

Source

Advances in Materials Science and Engineering

Issue

Vol. 2020, Issue 2020 (31 Dec. 2020), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2020-10-26

Country of Publication

Egypt

No. of Pages

8

Abstract EN

The water flow rate and galvanic current distribution in the T-shape junction of steel pipes were investigated using the multielectrode array approach.

The inner surface of polypropylene pipes junction was divided into 15 separate sections, and a steel plate was placed in every section to form a single inner surface.

The tap water flow rate varied between 0.28 and 0.57 m/s, and the water distribution in the junction was between 5 : 1 and 1 : 5.

The galvanic current flowing through each steel electrode was mapped on the 3D model of the T-shape junction.

Two differential aeration pairs were found with high anodic current densities.

American Psychological Association (APA)

Vasyliev, Georgii. 2020. Corrosion Localization Analysis in T-Shape Pipe Junction Based on Multielectrode Current Measurements. Advances in Materials Science and Engineering،Vol. 2020, no. 2020, pp.1-8.
https://search.emarefa.net/detail/BIM-1129056

Modern Language Association (MLA)

Vasyliev, Georgii. Corrosion Localization Analysis in T-Shape Pipe Junction Based on Multielectrode Current Measurements. Advances in Materials Science and Engineering No. 2020 (2020), pp.1-8.
https://search.emarefa.net/detail/BIM-1129056

American Medical Association (AMA)

Vasyliev, Georgii. Corrosion Localization Analysis in T-Shape Pipe Junction Based on Multielectrode Current Measurements. Advances in Materials Science and Engineering. 2020. Vol. 2020, no. 2020, pp.1-8.
https://search.emarefa.net/detail/BIM-1129056

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1129056