Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”

Joint Authors

Safak, Koray K.
Bozkurt, Selim

Source

Computational and Mathematical Methods in Medicine

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-1, 1 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-09-03

Country of Publication

Egypt

No. of Pages

1

Main Subjects

Medicine

Abstract EN

In the article titled “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations” [1], there were errors in equations (4) and (7) that should be corrected as follows:(1)In equation (4), the left ventricular volume change (dVlv/dt) was described as the difference between flow rates through the mitral valve (Qmv) and aortic valve (Qav).

The equation should be as follows:(4)dVlvdt=Qmv−Qav.(2)In equation (7), the HTA model and the circulatory system model were combined to simulate the CF-LVAD assistance using the equations which describe the left ventricular volume change (dVlv/dt) and systemic arterial pressure change (dpas/dt).

The equation should be corrected as follows:(7)dVlvdt=Qmv−Qav−QHTA,dpasdt=Qav+QHTA−QasCas.

American Psychological Association (APA)

Bozkurt, Selim& Safak, Koray K.. 2019. Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”. Computational and Mathematical Methods in Medicine،Vol. 2019, no. 2019, pp.1-1.
https://search.emarefa.net/detail/BIM-1130514

Modern Language Association (MLA)

Bozkurt, Selim& Safak, Koray K.. Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”. Computational and Mathematical Methods in Medicine No. 2019 (2019), pp.1-1.
https://search.emarefa.net/detail/BIM-1130514

American Medical Association (AMA)

Bozkurt, Selim& Safak, Koray K.. Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”. Computational and Mathematical Methods in Medicine. 2019. Vol. 2019, no. 2019, pp.1-1.
https://search.emarefa.net/detail/BIM-1130514

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1130514