Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”
Joint Authors
Source
Computational and Mathematical Methods in Medicine
Issue
Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-1, 1 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2019-09-03
Country of Publication
Egypt
No. of Pages
1
Main Subjects
Abstract EN
In the article titled “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations” [1], there were errors in equations (4) and (7) that should be corrected as follows:(1)In equation (4), the left ventricular volume change (dVlv/dt) was described as the difference between flow rates through the mitral valve (Qmv) and aortic valve (Qav).
The equation should be as follows:(4)dVlvdt=Qmv−Qav.(2)In equation (7), the HTA model and the circulatory system model were combined to simulate the CF-LVAD assistance using the equations which describe the left ventricular volume change (dVlv/dt) and systemic arterial pressure change (dpas/dt).
The equation should be corrected as follows:(7)dVlvdt=Qmv−Qav−QHTA,dpasdt=Qav+QHTA−QasCas.
American Psychological Association (APA)
Bozkurt, Selim& Safak, Koray K.. 2019. Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”. Computational and Mathematical Methods in Medicine،Vol. 2019, no. 2019, pp.1-1.
https://search.emarefa.net/detail/BIM-1130514
Modern Language Association (MLA)
Bozkurt, Selim& Safak, Koray K.. Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”. Computational and Mathematical Methods in Medicine No. 2019 (2019), pp.1-1.
https://search.emarefa.net/detail/BIM-1130514
American Medical Association (AMA)
Bozkurt, Selim& Safak, Koray K.. Corrigendum to “Evaluating the Hemodynamical Response of a Cardiovascular System under Support of a Continuous Flow Left Ventricular Assist Device via Numerical Modeling and Simulations”. Computational and Mathematical Methods in Medicine. 2019. Vol. 2019, no. 2019, pp.1-1.
https://search.emarefa.net/detail/BIM-1130514
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1130514