Measuring Tumor Metabolism in Pediatric Diffuse Intrinsic Pontine Glioma Using Hyperpolarized Carbon-13 MR Metabolic Imaging

Joint Authors

Autry, Adam W.
Hashizume, Rintaro
James, C. David
Larson, Peder E. Z.
Vigneron, Daniel B.
Park, Ilwoo

Source

Contrast Media & Molecular Imaging

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-07-30

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Diseases
Medicine

Abstract EN

Objective.

The purpose of this study was to demonstrate the feasibility of using hyperpolarized carbon-13 (13C) metabolic imaging with [1-13C]-labeled pyruvate for evaluating real-time in vivo metabolism of orthotopic diffuse intrinsic pontine glioma (DIPG) xenografts.

Materials and Methods.

3D 13C magnetic resonance spectroscopic imaging (MRSI) data were acquired on a 3T scanner from 8 rats that had been implanted with human-derived DIPG cells in the brainstem and 5 healthy controls, following injection of 2.5 mL (100 mM) hyperpolarized [1-13C]-pyruvate.

Results.

Anatomical images from DIPG-bearing rats characteristically exhibited T2-hyperintensity throughout the cerebellum and pons that was not accompanied by contrast enhancement.

Evaluation of real-time in vivo 13C spectroscopic data revealed ratios of lactate-to-pyruvate (p<0.002), lactate-to-total carbon (p<0.002), and normalized lactate (p<0.002) that were significantly higher in T2 lesions harboring tumor relative to corresponding values of healthy normal brain.

Elevated levels of lactate in lesions demonstrated a distinct metabolic profile that was associated with infiltrative, viable tumor recapitulating the histopathology of pediatric DIPG.

Conclusions.

Results from this study characterized pyruvate and lactate metabolism in orthotopic DIPG xenografts and suggest that hyperpolarized 13C MRSI may serve as a noninvasive imaging technique for in vivo monitoring of biochemical processes in patients with DIPG.

American Psychological Association (APA)

Autry, Adam W.& Hashizume, Rintaro& James, C. David& Larson, Peder E. Z.& Vigneron, Daniel B.& Park, Ilwoo. 2018. Measuring Tumor Metabolism in Pediatric Diffuse Intrinsic Pontine Glioma Using Hyperpolarized Carbon-13 MR Metabolic Imaging. Contrast Media & Molecular Imaging،Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1131356

Modern Language Association (MLA)

Autry, Adam W.…[et al.]. Measuring Tumor Metabolism in Pediatric Diffuse Intrinsic Pontine Glioma Using Hyperpolarized Carbon-13 MR Metabolic Imaging. Contrast Media & Molecular Imaging No. 2018 (2018), pp.1-6.
https://search.emarefa.net/detail/BIM-1131356

American Medical Association (AMA)

Autry, Adam W.& Hashizume, Rintaro& James, C. David& Larson, Peder E. Z.& Vigneron, Daniel B.& Park, Ilwoo. Measuring Tumor Metabolism in Pediatric Diffuse Intrinsic Pontine Glioma Using Hyperpolarized Carbon-13 MR Metabolic Imaging. Contrast Media & Molecular Imaging. 2018. Vol. 2018, no. 2018, pp.1-6.
https://search.emarefa.net/detail/BIM-1131356

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1131356