A Novel Double Side Branch Protection Technique for a Left Main Trifurcation Lesion: Simultaneous Jailed Balloon and Jailed Corsair Technique

Joint Authors

Munakata, Masahito
Ishikawa, Shiro
Koyama, Takashi
Numasawa, Yohei

Source

Case Reports in Cardiology

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-09-13

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Diseases

Abstract EN

Percutaneous coronary intervention for left main trifurcation disease is challenging.

Although side branch protection techniques such as the jailed balloon technique and jailed Corsair technique are the established methods for treatment of coronary bifurcation lesions, little is known regarding the application and feasibility of these techniques for left main trifurcation disease.

We herein describe a 72-year-old man with angina pectoris who was successfully treated with percutaneous coronary stent implantation for a left main trifurcation lesion.

In this case, we performed a novel double side branch protection technique, the simultaneous jailed balloon and jailed Corsair technique, with a single 8 Fr guiding catheter.

This is the first case report to highlight the feasibility and efficacy of combined use of the jailed balloon and jailed Corsair techniques during percutaneous coronary intervention for left main trifurcation disease.

American Psychological Association (APA)

Munakata, Masahito& Numasawa, Yohei& Ishikawa, Shiro& Koyama, Takashi. 2018. A Novel Double Side Branch Protection Technique for a Left Main Trifurcation Lesion: Simultaneous Jailed Balloon and Jailed Corsair Technique. Case Reports in Cardiology،Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1141183

Modern Language Association (MLA)

Munakata, Masahito…[et al.]. A Novel Double Side Branch Protection Technique for a Left Main Trifurcation Lesion: Simultaneous Jailed Balloon and Jailed Corsair Technique. Case Reports in Cardiology No. 2018 (2018), pp.1-5.
https://search.emarefa.net/detail/BIM-1141183

American Medical Association (AMA)

Munakata, Masahito& Numasawa, Yohei& Ishikawa, Shiro& Koyama, Takashi. A Novel Double Side Branch Protection Technique for a Left Main Trifurcation Lesion: Simultaneous Jailed Balloon and Jailed Corsair Technique. Case Reports in Cardiology. 2018. Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1141183

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1141183