Rehabilitation of Nose following Chemical Burn Using CADCAM Made Substructure for Implant Retained Nasal Prosthesis: A Clinical Report

Joint Authors

Chaturvedi, Saurabh
Bhagat, Tushar
Verma, A. K.
Gurumurthy, Vishwanath
Ali, Mariyam
Vadhwani, Preeti
Chaturvedi, Mudita

Source

Case Reports in Dentistry

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-06-18

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Dental

Abstract EN

Insufficient knowledge of medical chemicals and their improper use have destructive effects.

Accidental exposure to chemicals on facial tissue may result in large facial defect.

For ages the tradition of piercing nose is common but improper use of unknown chemical for piercing has deleterious effect.

Mostly rhinectomy defects are acquired caused by trauma or malignant diseases.

Prosthetic rehabilitation is the preferred treatment of choice for any large rhinectomy defects as medical and surgical interventions are ineffective in developing esthetics.

Main concern with the prosthesis for such defects is retention.

This article describes rehabilitation of a patient with large size nasal defect created by chemical burn in childhood during piercing.

Implant retained customized silicone nasal prosthesis was fabricated using simple O-ring attachments and innovative modified polyamide acrylic resin substructure acting as skeleton.

American Psychological Association (APA)

Chaturvedi, Saurabh& Bhagat, Tushar& Verma, A. K.& Gurumurthy, Vishwanath& Ali, Mariyam& Vadhwani, Preeti…[et al.]. 2017. Rehabilitation of Nose following Chemical Burn Using CADCAM Made Substructure for Implant Retained Nasal Prosthesis: A Clinical Report. Case Reports in Dentistry،Vol. 2017, no. 2017, pp.1-7.
https://search.emarefa.net/detail/BIM-1144592

Modern Language Association (MLA)

Chaturvedi, Saurabh…[et al.]. Rehabilitation of Nose following Chemical Burn Using CADCAM Made Substructure for Implant Retained Nasal Prosthesis: A Clinical Report. Case Reports in Dentistry No. 2017 (2017), pp.1-7.
https://search.emarefa.net/detail/BIM-1144592

American Medical Association (AMA)

Chaturvedi, Saurabh& Bhagat, Tushar& Verma, A. K.& Gurumurthy, Vishwanath& Ali, Mariyam& Vadhwani, Preeti…[et al.]. Rehabilitation of Nose following Chemical Burn Using CADCAM Made Substructure for Implant Retained Nasal Prosthesis: A Clinical Report. Case Reports in Dentistry. 2017. Vol. 2017, no. 2017, pp.1-7.
https://search.emarefa.net/detail/BIM-1144592

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1144592