A Case of Pacemaker Endocarditis Caused by Aerococcus urinae

Joint Authors

Rasmussen, Magnus
Samuelsson, Sandra
Kennergren, Charles

Source

Case Reports in Infectious Diseases

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-03-05

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Diseases

Abstract EN

Background.

Aerococcus urinae has lately been acknowledged as a cause of infective endocarditis (IE) especially in older males with underlying urinary tract disorders.

In this population, cardiac implanted electronical devices (CIED) are not uncommon, but despite the capacity of A.

urinae to form biofilm in vitro, no cases of aerococcal CIED infections have been reported to date.

Case Presentation.

An 84-year-old male with pacemaker was admitted with dysuria one month after a transurethral procedure for urinary bladder cancer.

A.

urinae was isolated from urine and blood.

Transesophageal echocardiography (TEE) was without signs of vegetation on valves or pacing cables.

The patient was treated with a twelve-day course of β-lactam antibiotics.

Forty days after the initial admission, the patient was readmitted due to malaise, general pain of the joints, chills, and renewed blood cultures grew A.

urinae.

TEE demonstrated a 10 × 5 mm vegetation on either the tricuspid valve or one of the pacing cables.

The pacemaker system was completely removed and demonstrated macroscopic signs of infection.

A temporary system was implanted, and after 14 days of penicillin G treatment, a new system permanent system was implanted.

Total treatment time was 40 days.

Recovery was uneventful.

Conclusion.

This report demonstrates that A.

urinae can cause CIED infection.

In patients with A.

urinae bacteremia and a CIED, this risk must be considered, especially if bacteremia reoccurs.

American Psychological Association (APA)

Samuelsson, Sandra& Kennergren, Charles& Rasmussen, Magnus. 2018. A Case of Pacemaker Endocarditis Caused by Aerococcus urinae. Case Reports in Infectious Diseases،Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1144697

Modern Language Association (MLA)

Samuelsson, Sandra…[et al.]. A Case of Pacemaker Endocarditis Caused by Aerococcus urinae. Case Reports in Infectious Diseases No. 2018 (2018), pp.1-3.
https://search.emarefa.net/detail/BIM-1144697

American Medical Association (AMA)

Samuelsson, Sandra& Kennergren, Charles& Rasmussen, Magnus. A Case of Pacemaker Endocarditis Caused by Aerococcus urinae. Case Reports in Infectious Diseases. 2018. Vol. 2018, no. 2018, pp.1-3.
https://search.emarefa.net/detail/BIM-1144697

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1144697