Extensor Tendons Rupture after Volar Plating of Distal Radius Fracture Related to a Dorsal Radial Metaphyseal Bone Spur

Joint Authors

Gallucci, Gerardo L.
De Cicco, Franco Luis
Abrego, M. O.
Boretto, J. G.
De Carli, P.

Source

Case Reports in Orthopedics

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-02-28

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Medicine

Abstract EN

Extensor tendon ruptures due to volar plating in distal radius fractures have mostly been described in relation with technique failures such as screw prominence and drill penetration.

We report the case of a 71-year-old female with a C2 distal radius fracture with severe dorsal metaphyseal comminution.

The patient underwent surgical treatment with reduction of the large fragments and fixation with a volar locking plate; the small dorsal metaphyseal nonarticular fragments were not reduced.

Six months later, the patient developed extensor digitorum communis (EDC) rupture and extensor indicis proprius (EIP) laceration in coincidence with the dorsal comminution turned into a bony spur.

The possible association between the extensor tendon injury and the dorsal residual metaphyseal bony spur in the distal radius fractures is unusual but should be taken into account in fracture patterns presenting dorsal comminution.

American Psychological Association (APA)

Abrego, M. O.& De Cicco, Franco Luis& Boretto, J. G.& Gallucci, Gerardo L.& De Carli, P.. 2018. Extensor Tendons Rupture after Volar Plating of Distal Radius Fracture Related to a Dorsal Radial Metaphyseal Bone Spur. Case Reports in Orthopedics،Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1148155

Modern Language Association (MLA)

Abrego, M. O.…[et al.]. Extensor Tendons Rupture after Volar Plating of Distal Radius Fracture Related to a Dorsal Radial Metaphyseal Bone Spur. Case Reports in Orthopedics No. 2018 (2018), pp.1-5.
https://search.emarefa.net/detail/BIM-1148155

American Medical Association (AMA)

Abrego, M. O.& De Cicco, Franco Luis& Boretto, J. G.& Gallucci, Gerardo L.& De Carli, P.. Extensor Tendons Rupture after Volar Plating of Distal Radius Fracture Related to a Dorsal Radial Metaphyseal Bone Spur. Case Reports in Orthopedics. 2018. Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1148155

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1148155