Successful Extubation Using Heliox BiPAP in Two Patients with Postextubation Stridor
Joint Authors
Newey, C. R.
George, P.
Nattanmai, Premkumar
Punj, Pragya
Source
Issue
Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-2, 2 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2017-03-08
Country of Publication
Egypt
No. of Pages
2
Main Subjects
Abstract EN
Postextubation stridor is associated with significant morbidity.
It commonly results in extubation failure after established medical treatment fails, such as nebulized epinephrine and/or intravenous steroids.
The role of heliox (i.e., combination of helium and oxygen) in managing patients with postextubation stridor has not been fully established.
We report two cases of postextubation stridor successfully treated with heliox delivered with bilevel positive airway pressure (BiPAP) after failure of standard medical therapy.
American Psychological Association (APA)
Punj, Pragya& Nattanmai, Premkumar& George, P.& Newey, C. R.. 2017. Successful Extubation Using Heliox BiPAP in Two Patients with Postextubation Stridor. Case Reports in Pulmonology،Vol. 2017, no. 2017, pp.1-2.
https://search.emarefa.net/detail/BIM-1149676
Modern Language Association (MLA)
Punj, Pragya…[et al.]. Successful Extubation Using Heliox BiPAP in Two Patients with Postextubation Stridor. Case Reports in Pulmonology No. 2017 (2017), pp.1-2.
https://search.emarefa.net/detail/BIM-1149676
American Medical Association (AMA)
Punj, Pragya& Nattanmai, Premkumar& George, P.& Newey, C. R.. Successful Extubation Using Heliox BiPAP in Two Patients with Postextubation Stridor. Case Reports in Pulmonology. 2017. Vol. 2017, no. 2017, pp.1-2.
https://search.emarefa.net/detail/BIM-1149676
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1149676