Response to: Comment on “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery”

Joint Authors

Jabbour, Pascal M.
Zanaty, Mario
Ryken, Katherine O.
Bulsara, Ketan R.
Chalouhi, Nohra
Starke, Robert M.
Hasan, David M.

Source

Case Reports in Vascular Medicine

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-1, 1 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-05-30

Country of Publication

Egypt

No. of Pages

1

Main Subjects

Diseases

Abstract EN

We would like to thank Dr.

Srinivasan and Dr.

Kan for their remarks [1] on our paper [2].

We think that these publications were developed simultaneously.

In addition, we think that more series would be reported in the future regarding the failure of the pipeline in the treatment of posterior communicating artery aneurysms associated with a fetal posterior cerebral artery.

We also congratulate Srinivasan et al.

[3] and Kan et al.

[4] on their work on this topic and we agree that the most likely explanation of the pipeline failure is the high flow demand in this type of circulation.

This can also explain why parent artery occlusion can lead to cerebellar infarction in this subset of patients [5].

We are also working on reporting other aneurysm geometrical factors that contribute to failure of flow-diversion; however this work is still in its early stages.

American Psychological Association (APA)

Zanaty, Mario& Chalouhi, Nohra& Starke, Robert M.& Jabbour, Pascal M.& Ryken, Katherine O.& Bulsara, Ketan R.…[et al.]. 2017. Response to: Comment on “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery”. Case Reports in Vascular Medicine،Vol. 2017, no. 2017, pp.1-1.
https://search.emarefa.net/detail/BIM-1150712

Modern Language Association (MLA)

Zanaty, Mario…[et al.]. Response to: Comment on “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery”. Case Reports in Vascular Medicine No. 2017 (2017), pp.1-1.
https://search.emarefa.net/detail/BIM-1150712

American Medical Association (AMA)

Zanaty, Mario& Chalouhi, Nohra& Starke, Robert M.& Jabbour, Pascal M.& Ryken, Katherine O.& Bulsara, Ketan R.…[et al.]. Response to: Comment on “Failure of the Pipeline Embolization Device in Posterior Communicating Artery Aneurysms Associated with a Fetal Posterior Cerebral Artery”. Case Reports in Vascular Medicine. 2017. Vol. 2017, no. 2017, pp.1-1.
https://search.emarefa.net/detail/BIM-1150712

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1150712