Misplacement of Tracheostomy Tube in the Right Main Bronchus: a Rare Complication

Joint Authors

Ziaian, Bijan
Shahriarirad, Reza
Erfani, Amirhossein
Amirian, Armin
Mardani, Parviz

Source

Case Reports in Surgery

Issue

Vol. 2020, Issue 2020 (31 Dec. 2020), pp.1-3, 3 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2020-02-14

Country of Publication

Egypt

No. of Pages

3

Main Subjects

Medicine

Abstract EN

A 38-year-old woman known case of metastatic squamous cell carcinoma of the cervical esophagus due to increasing dyspnea and stridor attributed to the pressure effect of the primary mass was scheduled for tracheostomy, which ended up in the right main bronchus.

This rare complication occurred using a tracheostomy tube number 7.5 via a vertical tracheotomy over 4th and 5th tracheal rings.

The misplacement was confirmed by chest X-ray and fiberoptic bronchoscopy, and the tracheostomy tube was successfully repositioned in a nonoperative approach.

American Psychological Association (APA)

Amirian, Armin& Shahriarirad, Reza& Ziaian, Bijan& Mardani, Parviz& Erfani, Amirhossein. 2020. Misplacement of Tracheostomy Tube in the Right Main Bronchus: a Rare Complication. Case Reports in Surgery،Vol. 2020, no. 2020, pp.1-3.
https://search.emarefa.net/detail/BIM-1151374

Modern Language Association (MLA)

Amirian, Armin…[et al.]. Misplacement of Tracheostomy Tube in the Right Main Bronchus: a Rare Complication. Case Reports in Surgery No. 2020 (2020), pp.1-3.
https://search.emarefa.net/detail/BIM-1151374

American Medical Association (AMA)

Amirian, Armin& Shahriarirad, Reza& Ziaian, Bijan& Mardani, Parviz& Erfani, Amirhossein. Misplacement of Tracheostomy Tube in the Right Main Bronchus: a Rare Complication. Case Reports in Surgery. 2020. Vol. 2020, no. 2020, pp.1-3.
https://search.emarefa.net/detail/BIM-1151374

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1151374