A Case of Lower-Pole Moiety Ureteral Stenosis Close to Ureteropelvic Junction in an Incomplete Duplicated Collecting System Managed by Retrograde Balloon Dilatation that Needed a 2nd Ureteral Stent to the Upper-Pole

Author

Saito, Seiichi

Source

Case Reports in Urology

Issue

Vol. 2020, Issue 2020 (31 Dec. 2020), pp.1-4, 4 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2020-07-16

Country of Publication

Egypt

No. of Pages

4

Main Subjects

Medicine

Abstract EN

A 71-year-old woman presented at our institution with the chief complaints of left back pain and fatigue.

Radiographic examination revealed left ureteral stenosis close to ureteropelvic junction of the lower-pole with a left incomplete duplicated collecting system.

Transurethral retrograde balloon dilatation under general anesthesia was performed, and a ureteral stent was inserted to the lower-pole; however, there was urinary leakage from the upper-pole at the dilated ureteral stenosis lesion, and therefore, another ureteral stent was inserted to the upper-pole just after the first stent insertion.

Both stents were removed at 6 weeks and subsequent intravenous pyelography confirmed resolution of the obstruction.

The patient has remained asymptomatic during 2 years of follow-up.

American Psychological Association (APA)

Saito, Seiichi. 2020. A Case of Lower-Pole Moiety Ureteral Stenosis Close to Ureteropelvic Junction in an Incomplete Duplicated Collecting System Managed by Retrograde Balloon Dilatation that Needed a 2nd Ureteral Stent to the Upper-Pole. Case Reports in Urology،Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1151842

Modern Language Association (MLA)

Saito, Seiichi. A Case of Lower-Pole Moiety Ureteral Stenosis Close to Ureteropelvic Junction in an Incomplete Duplicated Collecting System Managed by Retrograde Balloon Dilatation that Needed a 2nd Ureteral Stent to the Upper-Pole. Case Reports in Urology No. 2020 (2020), pp.1-4.
https://search.emarefa.net/detail/BIM-1151842

American Medical Association (AMA)

Saito, Seiichi. A Case of Lower-Pole Moiety Ureteral Stenosis Close to Ureteropelvic Junction in an Incomplete Duplicated Collecting System Managed by Retrograde Balloon Dilatation that Needed a 2nd Ureteral Stent to the Upper-Pole. Case Reports in Urology. 2020. Vol. 2020, no. 2020, pp.1-4.
https://search.emarefa.net/detail/BIM-1151842

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1151842