Stability of Propofol (2,6-Diisopropylphenol)‎ in Thermal Desorption Tubes during Air Transport

Joint Authors

Volk, Thomas
Sessler, Daniel I.
Maurer, Felix
Geiger, Martin
Kreuer, Sascha
Hüppe, Tobias

Source

International Journal of Analytical Chemistry

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-7, 7 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-05-02

Country of Publication

Egypt

No. of Pages

7

Main Subjects

Chemistry
Science

Abstract EN

The anesthetic propofol and other exhaled organic compounds can be sampled in Tenax sorbent tubes and analyzed by gas chromatography coupled with mass spectrometry.

The aim of this study was to evaluate the stability of propofol in Tenax sorbent tubes during overseas shipping.

This is relevant for international pharmacokinetic studies on propofol in exhaled air.

Tenax sorbent tube propofol samples with concentrations between 10 and 100 ng were prepared by liquid injection and with a calibration gas generator.

For each preparation method, one reference set was analyzed immediately after preparation, a second set was stored at room temperature, and a third one was stored refrigerated.

The fourth set was sent from Germany by airmail to USA and back.

The shipped set of tubes was analyzed when it returned after 55 days elapsed.

Then, the room temperature samples and the refrigerated stored samples were also analyzed.

To evaluate the stability of propofol in the stored and shipped tubes, we calculated the recovery rates of each sample set.

The mean recovery in the stored samples was 101.2% for the liquid preparation and 134.6% for the gaseous preparation at 4°C.

At 22°C, the recovery was 96.1% for liquid preparation and 92.1% for gaseous preparation, whereas the shipped samples had a recovery of 85.3% and 111.3%.

Thus, the deviation of the shipped samples is within a range of 15%, which is analytically acceptable.

However, the individual values show significantly larger deviations of up to -32.1% (liquid) and 30.9% (gaseous).

We conclude that storage of propofol on Tenax tubes at room temperature for 55 days is possible to obtain acceptable results.

However, it appears that due to severe temperature and pressure variations air shipment of propofol samples in Tenax tubes without cooling shows severe deviations from the initial concentration.

Although it was not tested in this study, we assume that refrigerated transport might be necessary to obtain comparable results as in the stored samples.

American Psychological Association (APA)

Maurer, Felix& Geiger, Martin& Volk, Thomas& Sessler, Daniel I.& Kreuer, Sascha& Hüppe, Tobias. 2019. Stability of Propofol (2,6-Diisopropylphenol) in Thermal Desorption Tubes during Air Transport. International Journal of Analytical Chemistry،Vol. 2019, no. 2019, pp.1-7.
https://search.emarefa.net/detail/BIM-1155874

Modern Language Association (MLA)

Maurer, Felix…[et al.]. Stability of Propofol (2,6-Diisopropylphenol) in Thermal Desorption Tubes during Air Transport. International Journal of Analytical Chemistry No. 2019 (2019), pp.1-7.
https://search.emarefa.net/detail/BIM-1155874

American Medical Association (AMA)

Maurer, Felix& Geiger, Martin& Volk, Thomas& Sessler, Daniel I.& Kreuer, Sascha& Hüppe, Tobias. Stability of Propofol (2,6-Diisopropylphenol) in Thermal Desorption Tubes during Air Transport. International Journal of Analytical Chemistry. 2019. Vol. 2019, no. 2019, pp.1-7.
https://search.emarefa.net/detail/BIM-1155874

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID