Accurate Determination of Boron Content in Halite by ICP-OES and ICP-MS

Joint Authors

Peng, Zhang-kuang
Liu, Zhi-na

Source

International Journal of Analytical Chemistry

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-05-29

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Chemistry
Science

Abstract EN

Boron element is widely distributed in different geologic bodies, and there are important geo-chemical applications in earth science.

Halite is a common mineral found in sediment basin.

However there is no good method to accurately measure the boron content in halite, which is mainly because Inductively Coupled Plasma Optical Emission Spectrometer (ICP-OES) and Inductively Coupled Plasma Mass Spectrometer (ICP-MS) are limited by the high salt matrix interference and the instrument detection limit.

Thus enriching the boron element and removing the matrix interference are necessary before the measuring.

In this paper, Amberlite IRA 743 boron-specific resin was applied to enrich the boron element and remove most of the high-salt matrix.

The strong acid cation resin (Dowex 50 W×8, 200-400 mesh, USA) and weak-base anion resin (Ion Exchanger II, Germany) were mixed with equal volume, which could remove the foreign ions completely: meanwhile, the relative content of boron in the solution reached above 98%, and the recoveries ranged from 97.8% to 104%.

208.900 nm was chosen as the detection wavelength for ICP-OES, and the detection identification and quantification limits were 0.006 mg·L−1 and 0.02 mg·L−1, respectively.

11B was chosen as the measuring element for ICP-MS, and the detection identification and quantification limits were severally 0.036 mg·L−1 and 0.12 mg·L−1.

The relative standard deviations ranged from 1.4% to 3.4% through six replicates under different salinities.

Therefore, the process could be regarded as a feasible method to measure boron content in halite by ICP-OES and ICP-MS.

American Psychological Association (APA)

Peng, Zhang-kuang& Liu, Zhi-na. 2019. Accurate Determination of Boron Content in Halite by ICP-OES and ICP-MS. International Journal of Analytical Chemistry،Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1156020

Modern Language Association (MLA)

Peng, Zhang-kuang& Liu, Zhi-na. Accurate Determination of Boron Content in Halite by ICP-OES and ICP-MS. International Journal of Analytical Chemistry No. 2019 (2019), pp.1-5.
https://search.emarefa.net/detail/BIM-1156020

American Medical Association (AMA)

Peng, Zhang-kuang& Liu, Zhi-na. Accurate Determination of Boron Content in Halite by ICP-OES and ICP-MS. International Journal of Analytical Chemistry. 2019. Vol. 2019, no. 2019, pp.1-5.
https://search.emarefa.net/detail/BIM-1156020

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1156020