A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step

Joint Authors

Santos, Felisberto G.
Reis, Boaventura F.

Source

Journal of Analytical Methods in Chemistry

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-03-05

Country of Publication

Egypt

No. of Pages

8

Main Subjects

Chemistry

Abstract EN

A highly sensitive analytical procedure for photometric determination of molybdenum in plant materials was developed and validated.

This procedure is based on the reaction of Mo(V) with thiocyanate ions (SCN−) in acidic medium to form a compound that can be monitored at 474 nm and was implemented employing a multicommuted flow analysis setup.

Photometric detection was performed using an LED-based photometer coupled to a flow cell with a long optical path length (200 mm) to achieve high sensitivity, allowing Mo(V) determination at a level of μg L−1 without the use of an organic solvent extraction step.

After optimization of operational conditions, samples of digested plant materials were analyzed employing the proposed procedure.

The accuracy was assessed by comparing the obtained results with those of a reference method, with an agreement observed at 95% confidence level.

In addition, a detection limit of 9.1 μg L−1, a linear response (r=0.9969) over the concentration range of 50–500 μg L−1, generation of only 3.75 mL of waste per determination, and a sampling rate of 51 determinations per hour were achieved.

American Psychological Association (APA)

Santos, Felisberto G.& Reis, Boaventura F.. 2017. A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step. Journal of Analytical Methods in Chemistry،Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1170359

Modern Language Association (MLA)

Santos, Felisberto G.& Reis, Boaventura F.. A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step. Journal of Analytical Methods in Chemistry No. 2017 (2017), pp.1-8.
https://search.emarefa.net/detail/BIM-1170359

American Medical Association (AMA)

Santos, Felisberto G.& Reis, Boaventura F.. A Highly Sensitive Multicommuted Flow Analysis Procedure for Photometric Determination of Molybdenum in Plant Materials without a Solvent Extraction Step. Journal of Analytical Methods in Chemistry. 2017. Vol. 2017, no. 2017, pp.1-8.
https://search.emarefa.net/detail/BIM-1170359

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1170359