Effect of Using a Cardiac Catheterization Table-Stabilizing Stick on the Quality of Cardiopulmonary Resuscitation in the Cardiac Catheterization Laboratory: A Simulation-Based Study

Joint Authors

Yamada, Tsuyoshi
Ito, Morihiro
Urai, Hisako
Ueda, Yumiko
Maki, Hiroaki
Baba, Reizo

Source

Journal of Interventional Cardiology

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-08-01

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Diseases

Abstract EN

Rapid defibrillation and high-quality cardiopulmonary resuscitation (CPR) are necessary for patients with cardiopulmonary arrest, one of the most serious and frequently encountered complications in cardiac catheterization laboratories.

However, when the catheterization table is withdrawn from its neutral position for fluoroscopy, it is unstable and unsuitable for resuscitation because of its cantilever structure.

To stabilize the table in its withdrawn position, the use of a table-stabilizing stick might improve CPR quality.

To investigate the effect of using a cardiac catheterization table-stabilizing stick on CPR quality, a CPR simulation mannequin was placed on a cardiac catheterization table that was withdrawn from the C-arm of the X-ray machine.

CPR quality was assessed with or without the use of a table-stabilizing stick under the table.

The CPR quality assessment (Q-CPR) scores were 79.6 ± 11.4% using the table-stabilizing stick and 47.7 ± 30.3% without the use of the stick device (p = 0.02).

In this simulation-based study, the use of a table-stabilizing stick in a cardiac catheterization table withdrawn from the C-arm of the X-ray machine improved the quality of CPR.

American Psychological Association (APA)

Yamada, Tsuyoshi& Ito, Morihiro& Urai, Hisako& Ueda, Yumiko& Maki, Hiroaki& Baba, Reizo. 2019. Effect of Using a Cardiac Catheterization Table-Stabilizing Stick on the Quality of Cardiopulmonary Resuscitation in the Cardiac Catheterization Laboratory: A Simulation-Based Study. Journal of Interventional Cardiology،Vol. 2019, no. 2019, pp.1-6.
https://search.emarefa.net/detail/BIM-1181247

Modern Language Association (MLA)

Yamada, Tsuyoshi…[et al.]. Effect of Using a Cardiac Catheterization Table-Stabilizing Stick on the Quality of Cardiopulmonary Resuscitation in the Cardiac Catheterization Laboratory: A Simulation-Based Study. Journal of Interventional Cardiology No. 2019 (2019), pp.1-6.
https://search.emarefa.net/detail/BIM-1181247

American Medical Association (AMA)

Yamada, Tsuyoshi& Ito, Morihiro& Urai, Hisako& Ueda, Yumiko& Maki, Hiroaki& Baba, Reizo. Effect of Using a Cardiac Catheterization Table-Stabilizing Stick on the Quality of Cardiopulmonary Resuscitation in the Cardiac Catheterization Laboratory: A Simulation-Based Study. Journal of Interventional Cardiology. 2019. Vol. 2019, no. 2019, pp.1-6.
https://search.emarefa.net/detail/BIM-1181247

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1181247