A Double Update PWM Method to Improve Robustness for the Deadbeat Current Controller in Three-Phase Grid-Connected System

Joint Authors

Chen, Yandong
Yang, Ling
Luo, An
Huai, Kunshan
Zhou, Leming
Zhou, Xiaoping
Wu, Wenhua
Tan, Wenjuan
Xie, Zhiwei

Source

Journal of Electrical and Computer Engineering

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-13, 13 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-06-07

Country of Publication

Egypt

No. of Pages

13

Main Subjects

Information Technology and Computer Science

Abstract EN

In the grid-connected inverter based on the deadbeat current control, the filter inductance variation and single update PWM affect the distortion of the grid current, stability, and dynamic of the system.

For this, a double update PWM method for the deadbeat current controller in three-phase grid-connected system is proposed, which not only effectively decreases the grid current distortion and control delay, but also improves the system stability and dynamic response speed due to reducing the characteristic root equation order of the closed-loop transfer function.

The influence of the filter inductance deviation coefficient on the system performance is analyzed.

As a conclusion, the corresponding filter inductance deviation coefficient in the system critical stability increases with increase in the parasitic resistance of the filter inductance and line equivalent resistance and decreases with increase in the sampling frequency.

Considering the system stability and dynamic response, the optimal range of the control parameters is acquired.

Simulation and experimental results verify the effectiveness of the proposed method.

American Psychological Association (APA)

Yang, Ling& Chen, Yandong& Luo, An& Huai, Kunshan& Zhou, Leming& Zhou, Xiaoping…[et al.]. 2018. A Double Update PWM Method to Improve Robustness for the Deadbeat Current Controller in Three-Phase Grid-Connected System. Journal of Electrical and Computer Engineering،Vol. 2018, no. 2018, pp.1-13.
https://search.emarefa.net/detail/BIM-1184409

Modern Language Association (MLA)

Yang, Ling…[et al.]. A Double Update PWM Method to Improve Robustness for the Deadbeat Current Controller in Three-Phase Grid-Connected System. Journal of Electrical and Computer Engineering No. 2018 (2018), pp.1-13.
https://search.emarefa.net/detail/BIM-1184409

American Medical Association (AMA)

Yang, Ling& Chen, Yandong& Luo, An& Huai, Kunshan& Zhou, Leming& Zhou, Xiaoping…[et al.]. A Double Update PWM Method to Improve Robustness for the Deadbeat Current Controller in Three-Phase Grid-Connected System. Journal of Electrical and Computer Engineering. 2018. Vol. 2018, no. 2018, pp.1-13.
https://search.emarefa.net/detail/BIM-1184409

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1184409