Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series

Joint Authors

Tsubota, Kazuo
Yuki, Kenya
Ozeki, Naoki
Shiba, Daisuke
Hosoda, Shingo
Yaguchi, Saori

Source

Journal of Ophthalmology

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-6, 6 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-02-07

Country of Publication

Egypt

No. of Pages

6

Main Subjects

Medicine

Abstract EN

Purpose.

To evaluate efficacy and safety of a trabecular micro-bypass stent system when used as the sole procedure in Japanese patients with medically uncontrolled primary open-angle glaucoma (POAG).

Design.

Prospective nonrandomized interventional pilot study.

Methods.

Ten eyes of 10 Japanese patients with medically uncontrolled POAG taking three ocular hypotensive medications were treated using only the implantation of two iStent trabecular micro-bypass stents.

Each patient continued to take the same ocular hypotensive medications used preoperatively throughout the study.

Intraocular pressure (IOP) and endothelial cell density (ECD) were determined at baseline and at 1, 3, and 6 months postoperatively.

Best-corrected visual acuity (BCVA) was measured at baseline and 6 months after surgery.

Results.

Mean IOP was 22.0±3.0 mmHg at baseline and 16.9±3.6 mmHg at 6 months, which represented a mean reduction of 5.1 mmHg or 23.2%.

No significant changes were observed in the ECD and BCVA.

Complications that occurred during the early postoperative period included hyphema, peripheral anterior synechiae, and occlusion of the stent by the iris.

Conclusion.

Implantation of two trabecular micro-bypass stents as the sole procedure in Japanese POAG patients effectively reduced IOP and exhibited a favorable safety profile.

Clinical Trials Registration number is UMIN000004002.

American Psychological Association (APA)

Shiba, Daisuke& Hosoda, Shingo& Yaguchi, Saori& Ozeki, Naoki& Yuki, Kenya& Tsubota, Kazuo. 2017. Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series. Journal of Ophthalmology،Vol. 2017, no. 2017, pp.1-6.
https://search.emarefa.net/detail/BIM-1185660

Modern Language Association (MLA)

Shiba, Daisuke…[et al.]. Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series. Journal of Ophthalmology No. 2017 (2017), pp.1-6.
https://search.emarefa.net/detail/BIM-1185660

American Medical Association (AMA)

Shiba, Daisuke& Hosoda, Shingo& Yaguchi, Saori& Ozeki, Naoki& Yuki, Kenya& Tsubota, Kazuo. Safety and Efficacy of Two Trabecular Micro-Bypass Stents as the Sole Procedure in Japanese Patients with Medically Uncontrolled Primary Open-Angle Glaucoma: A Pilot Case Series. Journal of Ophthalmology. 2017. Vol. 2017, no. 2017, pp.1-6.
https://search.emarefa.net/detail/BIM-1185660

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1185660