Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c)
Joint Authors
Zhou, Xingtao
Wang, Xiaoying
Chen, Xun
Han, Tian
Zhao, Feng
Miao, Huamao
Source
Issue
Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-6, 6 p.
Publisher
Hindawi Publishing Corporation
Publication Date
2019-08-14
Country of Publication
Egypt
No. of Pages
6
Main Subjects
Abstract EN
Purpose.
To investigate disk halo size changes produced by a glare source after surgical insertion of an implantable collamer lens with a central hole (ICL V4c) for myopia correction.
Methods.
In this prospective study, disk halo size and pupillary light response with a vision monitor were measured preoperatively and at 1 week, 1 month, and 3 months postoperatively.
Pupillary light response parameters included contraction amplitude, latency, duration, and velocity; dilation latency, duration, and velocity; and initial, maximum, minimum, and average pupil diameters.
Results.
Forty-two right eyes of 42 patients were enrolled.
Postoperative uncorrected distance visual acuity was better than or equal to 20/20 in all eyes.
Compared to preoperative values, disk halo size showed no significant difference at 1 week postoperatively (P>0.05) and then decreased significantly at 1 and 3 months postoperatively (both P<0.001).
Contraction amplitude and velocity, as well as dilation velocity, decreased significantly at all postoperative time points (all P<0.001).
Disk halo size at 3 months postoperatively was significantly correlated with initial (r = 0.446, P=0.003), maximum (r = 0.483, P=0.001), minimum (r = 0.425, P=0.005), and average pupil diameters (r = 0.474, P=0.002).
Conclusions.
After ICL V4c implantation, disk halo size was reduced in the short term.
Patients with smaller pupil sizes during pupillary response to light experienced smaller halos after ICL V4c implantation.
American Psychological Association (APA)
Chen, Xun& Han, Tian& Zhao, Feng& Miao, Huamao& Wang, Xiaoying& Zhou, Xingtao. 2019. Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c). Journal of Ophthalmology،Vol. 2019, no. 2019, pp.1-6.
https://search.emarefa.net/detail/BIM-1186062
Modern Language Association (MLA)
Chen, Xun…[et al.]. Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c). Journal of Ophthalmology No. 2019 (2019), pp.1-6.
https://search.emarefa.net/detail/BIM-1186062
American Medical Association (AMA)
Chen, Xun& Han, Tian& Zhao, Feng& Miao, Huamao& Wang, Xiaoying& Zhou, Xingtao. Evaluation of Disk Halo Size after Implantation of a Collamer Lens with a Central Hole (ICL V4c). Journal of Ophthalmology. 2019. Vol. 2019, no. 2019, pp.1-6.
https://search.emarefa.net/detail/BIM-1186062
Data Type
Journal Articles
Language
English
Notes
Includes bibliographical references
Record ID
BIM-1186062