Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors

Joint Authors

Koyama, Shouhei
Ishizawa, Hiroaki
Sakaguchi, Akio
Hosoya, Satoshi
Kawamura, Takashi

Source

Journal of Sensors

Issue

Vol. 2017, Issue 2017 (31 Dec. 2017), pp.1-10, 10 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2017-07-24

Country of Publication

Egypt

No. of Pages

10

Main Subjects

Civil Engineering

Abstract EN

We studied a wearable blood pressure sensor using a fiber Bragg grating (FBG) sensor, which is a highly accurate strain sensor.

This sensor is installed at the pulsation point of the human body to measure the pulse wave signal.

A calibration curve is built that calculates the blood pressure by multivariate analysis using the pulse wave signal and a reference blood pressure measurement.

However, if the measurement height of the FBG sensor is different from the reference measurement height, an error is included in the reference blood pressure.

We verified the accuracy of the blood pressure calculation with respect to the measurement height difference and the posture of the subject.

As the difference between the measurement height of the FBG sensor and the reference blood pressure measurement increased, the accuracy of the blood pressure calculation decreased.

When the measurement height was identical and only posture was changed, good accuracy was achieved.

In addition, when calibration curves were built using data measured in multiple postures, the blood pressure of each posture could be calculated from a single calibration curve.

This will allow miniaturization of the necessary electronics of the sensor system, which is important for a wearable sensor.

American Psychological Association (APA)

Koyama, Shouhei& Ishizawa, Hiroaki& Sakaguchi, Akio& Hosoya, Satoshi& Kawamura, Takashi. 2017. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors. Journal of Sensors،Vol. 2017, no. 2017, pp.1-10.
https://search.emarefa.net/detail/BIM-1187609

Modern Language Association (MLA)

Koyama, Shouhei…[et al.]. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors. Journal of Sensors No. 2017 (2017), pp.1-10.
https://search.emarefa.net/detail/BIM-1187609

American Medical Association (AMA)

Koyama, Shouhei& Ishizawa, Hiroaki& Sakaguchi, Akio& Hosoya, Satoshi& Kawamura, Takashi. Influence on Calculated Blood Pressure of Measurement Posture for the Development of Wearable Vital Sign Sensors. Journal of Sensors. 2017. Vol. 2017, no. 2017, pp.1-10.
https://search.emarefa.net/detail/BIM-1187609

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1187609