Dynamic Characteristics of Gas Explosion and Its Mitigation Measures inside Residential Buildings

Joint Authors

Cen, Kang
Song, Bin
Wang, Qingsheng
Shen, Ruiqing
Zhang, Yidong
Yu, Wuge

Source

Mathematical Problems in Engineering

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-15, 15 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-04-23

Country of Publication

Egypt

No. of Pages

15

Main Subjects

Civil Engineering

Abstract EN

Currently, there is very limited understanding of a gas explosion process inside residential buildings.

In this study, a numerical model of gas explosion in a residential building was developed using Computational Fluid Dynamics (CFD).

The numerical simulations were performed for different gas cloud filling regions and equivalence ratios to identify the initial scenario, and the simulation results were compared with the real consequences of gas explosion.

Additionally, the temporal and spatial evolvement characteristics of explosion overpressure and indoor temperature were analyzed.

Furthermore, the effects of vent area ratio and the activation pressure of vent panels in the kitchen were investigated to propose effective mitigation measures for the gas explosions inside residential buildings.

The results show that the simulation results reproduced by the CFD model are in good agreement with the real accident consequences.

During the explosion process, the overpressure distribution in a room is almost uniform at the same moment and there exists little spatial difference.

The maximum temperature can reach up to 1953°C, which can cause secondary fire accidents easily.

The maximum flame speed is in the range of 34.3 m/s and 230.9 m/s.

It indicates that gas explosion inside residential buildings is a typical deflagration process.

When the vent area ratio is less than 0.3, the overpressure peaks decrease rapidly with the increase of the vent area ratio.

However, when the vent area ratio is larger than 0.3, the overpressure peaks are almost independent on the vent area ratio.

There is a proportional relationship between the overpressure peaks and the activation pressure of vent panels.

These achievements provide reliable reference data for the accident investigation of gas explosion and subsequent treatment.

American Psychological Association (APA)

Cen, Kang& Song, Bin& Shen, Ruiqing& Zhang, Yidong& Yu, Wuge& Wang, Qingsheng. 2019. Dynamic Characteristics of Gas Explosion and Its Mitigation Measures inside Residential Buildings. Mathematical Problems in Engineering،Vol. 2019, no. 2019, pp.1-15.
https://search.emarefa.net/detail/BIM-1194622

Modern Language Association (MLA)

Cen, Kang…[et al.]. Dynamic Characteristics of Gas Explosion and Its Mitigation Measures inside Residential Buildings. Mathematical Problems in Engineering No. 2019 (2019), pp.1-15.
https://search.emarefa.net/detail/BIM-1194622

American Medical Association (AMA)

Cen, Kang& Song, Bin& Shen, Ruiqing& Zhang, Yidong& Yu, Wuge& Wang, Qingsheng. Dynamic Characteristics of Gas Explosion and Its Mitigation Measures inside Residential Buildings. Mathematical Problems in Engineering. 2019. Vol. 2019, no. 2019, pp.1-15.
https://search.emarefa.net/detail/BIM-1194622

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1194622