Application of 25 MHz B-Scan Ultrasonography to Determine the Integrity of the Posterior Capsule in Posterior Polar Cataract

Joint Authors

Li, Jun
Yuan, Xiaoyong
Wu, Bin
Gao, Jianmin
Lu, Chengzhe
Tang, Xin
Guo, Yawen

Source

Journal of Ophthalmology

Issue

Vol. 2018, Issue 2018 (31 Dec. 2018), pp.1-5, 5 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2018-03-26

Country of Publication

Egypt

No. of Pages

5

Main Subjects

Medicine

Abstract EN

Purpose.

To report the application of 25 MHz B-scan ultrasonography (MHzB) to determine the integrity of the posterior capsule (PC) in posterior polar cataract (PPC).

Methods.

Patients with whom PPC was clinically diagnosed using slit lamp microscopy who underwent 25 MHzB before phacoemulsification were retrospectively reviewed.

The status of the PC was determined by 25 MHzB before phacoemulsification and confirmed during cataract surgery.

Results.

In total, 21 eyes in 14 clinically diagnosed PPC patients were enrolled in this study.

Out of 25 MHzB images, 19 PCs were found to be intact, while 2 showed dehiscence before cataract surgery.

During phacoemulsification, 17 PCs were observed to be intact, while 4 PCs showed posterior capsule rupture (PCR).

These 4 PCR cases included the above 2 eyes, in which preexisting dehiscence was detected by 25 MHzB.

The other 2 PCR cases showed high reflectivity between high echoes in posterior opacities and the PC, indicating synechia between the PPC and PC.

Conclusion.

This is the first report to show that 25 MHzB can be used to clearly visualize the status of the PC in PPC.

These results, in turn, could be used to select the appropriate treatment and to thereby avoid further complications during PPC surgery.

American Psychological Association (APA)

Guo, Yawen& Lu, Chengzhe& Wu, Bin& Gao, Jianmin& Li, Jun& Yuan, Xiaoyong…[et al.]. 2018. Application of 25 MHz B-Scan Ultrasonography to Determine the Integrity of the Posterior Capsule in Posterior Polar Cataract. Journal of Ophthalmology،Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1197213

Modern Language Association (MLA)

Guo, Yawen…[et al.]. Application of 25 MHz B-Scan Ultrasonography to Determine the Integrity of the Posterior Capsule in Posterior Polar Cataract. Journal of Ophthalmology No. 2018 (2018), pp.1-5.
https://search.emarefa.net/detail/BIM-1197213

American Medical Association (AMA)

Guo, Yawen& Lu, Chengzhe& Wu, Bin& Gao, Jianmin& Li, Jun& Yuan, Xiaoyong…[et al.]. Application of 25 MHz B-Scan Ultrasonography to Determine the Integrity of the Posterior Capsule in Posterior Polar Cataract. Journal of Ophthalmology. 2018. Vol. 2018, no. 2018, pp.1-5.
https://search.emarefa.net/detail/BIM-1197213

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1197213