Comparative Analysis between PI and Linear-ADRC Control of a Grid Connected Variable Speed Wind Energy Conversion System Based on a Squirrel Cage Induction Generator

Joint Authors

Laghridat, Hammadi
Essadki, Ahmed
Nasser, Tamou

Source

Mathematical Problems in Engineering

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-16, 16 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-03-26

Country of Publication

Egypt

No. of Pages

16

Main Subjects

Civil Engineering

Abstract EN

This paper aims at contributing to the modeling and control of a variable speed Wind Energy Conversion System (WEC-System) based on a Squirrel Cage Induction Generator (SCI-Generator).

The connection between the SCI-Generator and the main utility grid is achieved by back-to-back three phase power converters (Generator and Grid Side Converters).

A new control strategy named the Active Disturbance Rejection Control (ADRC) is proposed and utilized to control the Wind Energy Conversion (WEC) system based on the SCI-Generator.

The objective is to control both the generator and the grid side converters in order to operate the system and to ensure the connection with the power grid.

The first converter is used to control the SCI-Generator speed and field to extract the available maximum power from the wind turbine by using a Maximum Power Point Tracking (MPPT) technique and, also, to ensure that the extracted power does not exceed its rated value in case of strong wind speeds; in this case a pitch actuator system is used to control the blades pitch angle of the wind turbine.

The second converter is used to control the active and reactive powers injected into the utility grid as well as to regulate the DC-Link Voltage.

This control takes into account the rejection of internal disturbances as the variation of electrical parameters (the resistance, the inductance…) and the external disturbances as voltage dips and frequency droops in the main grid.

To test and validate the performances of the proposed controller, a series of simulations were developed under MATLAB/Simulink environment, and the results have demonstrated the effectiveness of the proposed control under different case of simulations.

American Psychological Association (APA)

Laghridat, Hammadi& Essadki, Ahmed& Nasser, Tamou. 2019. Comparative Analysis between PI and Linear-ADRC Control of a Grid Connected Variable Speed Wind Energy Conversion System Based on a Squirrel Cage Induction Generator. Mathematical Problems in Engineering،Vol. 2019, no. 2019, pp.1-16.
https://search.emarefa.net/detail/BIM-1197703

Modern Language Association (MLA)

Laghridat, Hammadi…[et al.]. Comparative Analysis between PI and Linear-ADRC Control of a Grid Connected Variable Speed Wind Energy Conversion System Based on a Squirrel Cage Induction Generator. Mathematical Problems in Engineering No. 2019 (2019), pp.1-16.
https://search.emarefa.net/detail/BIM-1197703

American Medical Association (AMA)

Laghridat, Hammadi& Essadki, Ahmed& Nasser, Tamou. Comparative Analysis between PI and Linear-ADRC Control of a Grid Connected Variable Speed Wind Energy Conversion System Based on a Squirrel Cage Induction Generator. Mathematical Problems in Engineering. 2019. Vol. 2019, no. 2019, pp.1-16.
https://search.emarefa.net/detail/BIM-1197703

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID