Hearing Thresholds Changes after MRI 1.5T of Head and Neck

Joint Authors

Davari, Mohammad Hossein
Mirmohammadi, Seyyed Jalil
Zare Sakhvidi, Mohammad Javad
Mehrparvar, Amir Houshang
Sobhan, Mohammad
Jalalian, Mohammad Taghi
Shamsi, Farimah
Mirfendereski, Sam
Bahaloo, Maryam
Mollasadeghi, Abolfazl

Source

Radiology Research and Practice

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-4, 4 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-06-17

Country of Publication

Egypt

No. of Pages

4

Main Subjects

Medicine

Abstract EN

Introduction.

Exposure to high intensity noise produced by MRI is a cause for concern.

This study was conducted to determine the temporary and permanent effects of exposure to noise created by performing MRI on the hearing threshold of the subjects using conventional and extended high frequency audiometry.

Methods.

This semiexperimental study was performed on 35 patients referred to Shahid Rahnemoun Hospital for head and neck MRI due to different clinical conditions.

The hearing threshold of patients was measured before, immediately after, and 24 hours after performing 1.5 Tesla MRI using conventional and extended high frequency audiometry.

SPSS version 18 was used to compare the mean hearing thresholds before and after MRI using paired T test and repeated measures analysis.

Results.

Comparison of auditory thresholds in conventional and extended high frequencies before and immediately after MRI showed a significant shift at 4 KHz (P = 0.008 and P = 0.08 for right and left ears), 6 KHz (P = 0.03 and P = 0.01 for right and left ears), and 14 KHz (P =0.03 and P = 0.31 for right and left ears).

However, there was no significant difference between audiometric thresholds before and 24 hours after MRI.

Conclusion.

Noise due to 1.5 Tesla MRI can only cause transient threshold shift.

American Psychological Association (APA)

Bahaloo, Maryam& Davari, Mohammad Hossein& Sobhan, Mohammad& Mirmohammadi, Seyyed Jalil& Jalalian, Mohammad Taghi& Zare Sakhvidi, Mohammad Javad…[et al.]. 2019. Hearing Thresholds Changes after MRI 1.5T of Head and Neck. Radiology Research and Practice،Vol. 2019, no. 2019, pp.1-4.
https://search.emarefa.net/detail/BIM-1207588

Modern Language Association (MLA)

Bahaloo, Maryam…[et al.]. Hearing Thresholds Changes after MRI 1.5T of Head and Neck. Radiology Research and Practice No. 2019 (2019), pp.1-4.
https://search.emarefa.net/detail/BIM-1207588

American Medical Association (AMA)

Bahaloo, Maryam& Davari, Mohammad Hossein& Sobhan, Mohammad& Mirmohammadi, Seyyed Jalil& Jalalian, Mohammad Taghi& Zare Sakhvidi, Mohammad Javad…[et al.]. Hearing Thresholds Changes after MRI 1.5T of Head and Neck. Radiology Research and Practice. 2019. Vol. 2019, no. 2019, pp.1-4.
https://search.emarefa.net/detail/BIM-1207588

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1207588