Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted DesignComputer-Assisted Manufacturing (CADCAM)‎ Polyether-Ether-Ketone (PEEK)‎ Implant-Supported Bars for Maxillary Overdentures

Joint Authors

Mangano, Francesco Guido
Margiani, Bidzina
Admakin, Oleg
Mangano, Carlo

Source

Scanning

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-14, 14 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-08-22

Country of Publication

Egypt

No. of Pages

14

Main Subjects

Information Technology and Computer Science

Abstract EN

Purpose.

To present a digital method that combines intraoral and face scanning for the computer-assisted design/computer-assisted manufacturing (CAD/CAM) fabrication of implant-supported bars for maxillary overdentures.

Methods.

Over a 2-year period, all patients presenting to a private dental clinic with a removable complete denture in the maxilla, seeking rehabilitation with implants, were considered for inclusion in this study.

Inclusion criteria were fully edentulous maxilla, functional problems with the preexisting denture, opposing dentition, and sufficient bone volume to insert four implants.

Exclusion criteria were age<55 years, need for bone augmentation, uncompensated diabetes mellitus, immunocompromised status, radio- and/or chemotherapy, and previous treatment with oral and/or intravenous aminobisphosphonates.

All patients were rehabilitated with a maxillary overdenture supported by a CAD/CAM polyether-ether-ketone (PEEK) implant-supported bar.

The outcomes of the study were the passive fit/adaptation of the bar, the 1-year implant survival, and the success rates of the implant-supported overdentures.

Results.

15 patients (6 males, 9 females; mean age 68.8±4.7 years) received 60 implants and were rehabilitated with a maxillary overdenture supported by a PEEK bar, designed and milled from an intraoral digital impression.

The intraoral scans were integrated with face scans, in order to design each bar with all available patient data (soft tissues, prosthesis, implants, and face) in the correct spatial position.

When testing the 3D-printed resin bar, 12 bars out of 15 (80%) had a perfect passive adaptation and fit; in contrast, 3 out of 15 (20%) did not have a sufficient passive fit or adaptation.

No implants were lost, for a 1-year survival of 100% (60/60 surviving implants).

However, some complications (two fixtures with peri-implantitis in the same patient and two repaired overdentures in two different patients) occurred.

This determined a 1-year success rate of 80% for the implant-supported overdenture.

Conclusions.

In this study, the combination of intraoral and face scans allowed to successfully restore fully edentulous patients with maxillary overdentures supported by 4 implants and a CAD/CAM PEEK bar.

Further studies are needed to confirm these outcomes.

American Psychological Association (APA)

Mangano, Francesco Guido& Mangano, Carlo& Margiani, Bidzina& Admakin, Oleg. 2019. Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted DesignComputer-Assisted Manufacturing (CADCAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures. Scanning،Vol. 2019, no. 2019, pp.1-14.
https://search.emarefa.net/detail/BIM-1207922

Modern Language Association (MLA)

Mangano, Francesco Guido…[et al.]. Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted DesignComputer-Assisted Manufacturing (CADCAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures. Scanning No. 2019 (2019), pp.1-14.
https://search.emarefa.net/detail/BIM-1207922

American Medical Association (AMA)

Mangano, Francesco Guido& Mangano, Carlo& Margiani, Bidzina& Admakin, Oleg. Combining Intraoral and Face Scans for the Design and Fabrication of Computer-Assisted DesignComputer-Assisted Manufacturing (CADCAM) Polyether-Ether-Ketone (PEEK) Implant-Supported Bars for Maxillary Overdentures. Scanning. 2019. Vol. 2019, no. 2019, pp.1-14.
https://search.emarefa.net/detail/BIM-1207922

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1207922