Three-Dimensional Measurement of TRISO Coated Particle Using Micro Computed Tomography

Joint Authors

Xiang, Xincheng
Wang, Xiangang
Zhu, Libing
Peng, Yahui

Source

Science and Technology of Nuclear Installations

Issue

Vol. 2019, Issue 2019 (31 Dec. 2019), pp.1-8, 8 p.

Publisher

Hindawi Publishing Corporation

Publication Date

2019-03-03

Country of Publication

Egypt

No. of Pages

8

Abstract EN

The fuel safety and performance of high-temperature gas-cooled reactor (HTGR) are dependent on the integrity and geometric parameter of Tri-structural Isotropic (TRISO) coated particle.

Micro X-ray computed tomography (CT) was used for nondestructive testing and three-dimensional measurement of the particle components which are composed of kernel, buffer layer, inner pyrolytic carbon layer (IPyC), silicon carbide (SiC) layer, and outer pyrolytic carbon (OPyC) layer.

The thickness distribution and volume of kernel and coating layers are obtained by constructing 3D volume rendering of TRISO particle.

Mean thickness of each layer is calculated for comparison with design value.

A comparison between two-dimensional and three-dimensional measurement results is also made.

It is found that the thickness distribution of all layers approximately obeys Gaussian distribution.

Deviation of the thickness of kernel and coating layers between 3D measurement result and design value is 7.88%, -25.63%, -45.50%, 13.87%, and 14.73%, respectively.

The deviation will affect the failure probability of TRISO particle.

Obvious difference of the OPyC mean thickness between 3D measurement and 2D measurement is found, which proves that the proposed 3D measurement provides comprehensive information of the particle.

However, 2D and 3D measured thickness of the kernel and IPyC layer tend to be similar.

American Psychological Association (APA)

Zhu, Libing& Xiang, Xincheng& Peng, Yahui& Wang, Xiangang. 2019. Three-Dimensional Measurement of TRISO Coated Particle Using Micro Computed Tomography. Science and Technology of Nuclear Installations،Vol. 2019, no. 2019, pp.1-8.
https://search.emarefa.net/detail/BIM-1210818

Modern Language Association (MLA)

Zhu, Libing…[et al.]. Three-Dimensional Measurement of TRISO Coated Particle Using Micro Computed Tomography. Science and Technology of Nuclear Installations No. 2019 (2019), pp.1-8.
https://search.emarefa.net/detail/BIM-1210818

American Medical Association (AMA)

Zhu, Libing& Xiang, Xincheng& Peng, Yahui& Wang, Xiangang. Three-Dimensional Measurement of TRISO Coated Particle Using Micro Computed Tomography. Science and Technology of Nuclear Installations. 2019. Vol. 2019, no. 2019, pp.1-8.
https://search.emarefa.net/detail/BIM-1210818

Data Type

Journal Articles

Language

English

Notes

Includes bibliographical references

Record ID

BIM-1210818